Matters ▸ Attachment
Rooftop Mechanicals — File 212308
117
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4.1.7. Apartment Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration (min/max)
15%
50%
Facade Build Out (min)
--
B
Upper Story Fenestration (min/max)
15%
50%
Primary Front
80%
Blank Wall (max)
20 ft
Secondary Front
65%
B
Floor plate (max)
15,000 sf
Use & Occupancy
Ground Story Elevation (min)
2 ft
Density Factor (min)
--
C
Story Height (min)
10 ft
Lot Area < 5,000 sf
1,500
D
Number of Stories (min/max)
2
3
Lot Area >= 5,000 sf
1,125
E
Building Height, Feet (max)
38 ft
Net Zero Ready Building
850
Roof Type
Flat
Outdoor Amenity Space (min)
1/DU
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
10 ft
121
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4.1.8. General Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
50%
B
Floor plate (max)
15,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
14 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
2
3
Ground Story Entrance Spacing (max)
30 ft
F
Building Height, Feet (max)
40 ft
Commercial Space Depth (min)
30 ft
Roof Type
Flat
Density Factor (min)
--
Lot Area < 5,000 sf
1,500
Lot Area >= 5,000 sf
1,125
Net Zero Ready Building
850
Outdoor Amenity Space (min)
1/DU
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
10 ft
125
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4.1.9 Commercial Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out, (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
70%
B
Floor plate (max)
15,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
14 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
2
3
Ground Story Entrance Spacing (max)
30 ft
F
Building Height, Feet (max)
42 ft
Commercial Space Depth (min)
30 ft
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
10 ft
136
| SOMERVILLE ZONING ORDINANCE
12/12/2019
4. Mid-rise Districts
Mid-Rise 3 (MR3)
4. Mid-rise Districts
Mid-Rise 3 (MR3)
14. Development Standards
a. General
i.
Development is subject to the provisions of Article
10: Development Standards of this Ordinance.
Where the provisions of this section conflict with
those of Article 10, the provisions of Article 10
apply.
b. Signs
i.
A sign, individual numerals or letters, or a
nonelectrical nameplate identifying the property
address is required for all real property as follows:
a). Each ground story non-residential use must
identify the street address either on the
principal entrance door or above or beside the
principal entrance of the use.
b). All residential building types must identify the
street address either on the principal entrance
door, above or beside the principal entrance, or
on a mailbox.
ii.
Address signs must be made easily visible through
the use of colors or materials that contrast with the
background material they are attached to and must
be conspicuously located to provide visibility from
the thoroughfare that the building faces.
iii. Address signs must be twelve (12) inches in height
or less and may include the name of the occupant.
c. Roof-Mounted Mechanicals
i.
Roof mounted mechanical equipment must be
screened or enclosed within a rooftop penthouse.
a). Roof-mounted photovoltaic (PV) devices are
exempt.
ii.
Mechanical equipment, screening, and rooftop
mechanical penthouses may exceed the maximum
height permitted for each building type by Special
Permit.
a). In addition to the review criteria for all Special
Permits specified in §15.2.1.e. Review
Criteria, the review board shall make findings
considering the following in its discretion to
approve or deny a special permit authorizing
mechanical equipment, screening, or rooftop
mechanical penthouse to exceed the maximum
height permitted for each building type:
i). Reserved
Table 4.1.13 Permitted Uses (continued)
Use Category
Specific Use
MR3
Accessory Uses
Home Occupations (as noted below)
--
Creative Studio
N
Hobby Kennel
N
Home-Based Business
N
Home Day Care
N
Home Office
P
Urban Agriculture (as noted below)
--
Apiculture
P
Aviculture
P
Commercial Farming
P
Residential Gardening
P
Vehicle Parking, Accessory
(except as follows)
P
Home Business Vehicle Parking
N
P - Permitted SP - Special Permit Required N - Not Permitted
(P or SP) - Permitted as specified per §4.1.13.b
145
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 4 (MR4)
145
SOMERVILLE ZONING ORDINANCE |
4. Mid-rise Districts
Mid-Rise 4 (MR4)
4.2.7. Apartment Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration (min/max)
15%
50%
Facade Build Out (min)
--
B
Upper Story Fenestration (min/max)
15%
50%
Primary Front
80%
Blank Wall (max)
20 ft
Secondary Front
65%
B
Floor plate (max)
15,000 sf
Use & Occupancy
Ground Story Elevation (min)
2 ft
Density Factor (min)
--
C
Story Height (min)
10 ft
Lot Area < 5,500 sf
1,500
D
Number of Stories (min/max)
3
4
Lot Area >= 5,500 sf
1,125
E
Building Height, Feet (max)
50 ft
Net Zero Ready Building
850
Roof Type
Flat
Outdoor Amenity Space (min)
1/DU
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
10 ft
149
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 4 (MR4)
149
SOMERVILLE ZONING ORDINANCE |
4. Mid-rise Districts
Mid-Rise 4 (MR4)
4.2.8. General Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
50%
B
Floor plate (max)
15,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
14 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min)
3
4
Ground Story Entrance Spacing (max)
30 ft
F
Building Height, Feet (max)
52 ft
Commercial Space Depth (min)
30 ft
Roof Type
Flat
Density Factor (min)
--
Lot Area < 5,500 sf
1,500
Lot Area >= 5,500 sf
1,125
Net Zero Ready Building
850
Outdoor Amenity Space (min)
1/DU
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
10 ft
153
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 4 (MR4)
153
SOMERVILLE ZONING ORDINANCE |
4. Mid-rise Districts
Mid-Rise 4 (MR4)
4.2.9. Commercial Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
70%
B
Floor plate (max)
15,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
14 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
3
4
Principal Entrance Spacing (max)
30 ft
F
Building Height, Feet (max)
55 ft
Commercial Space Depth (min)
30 ft
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
10 ft
164
| SOMERVILLE ZONING ORDINANCE
12/12/2019
4. Mid-rise Districts
Mid-Rise 4 (MR4)
164
| SOMERVILLE ZONING ORDINANCE
4. Mid-rise Districts
Mid-Rise 4 (MR4)
14. Development Standards
a. General
i.
Development is subject to the provisions of Article
10: Development Standards of this Ordinance.
Where the provisions of this section conflict with
those of Article 10, the provisions of Article 10
apply.
b. Signs
i.
A sign, individual numerals or letters, or a
nonelectrical nameplate identifying the property
address is required for all real property as follows:
a). Each ground story non-residential use must
identify the street address either on the
principal entrance door or above or beside the
principal entrance of the use.
b). All residential building types must identify the
street address either on the principal entrance
door, above or beside the principal entrance, or
on a mailbox.
ii.
Address signs must be made easily visible through
the use of colors or materials that contrast with the
background material they are attached to and must
be conspicuously located to provide visibility from
the thoroughfare that the building faces.
iii. Address signs must be twelve (12) inches in height
or less and may include the name of the occupant.
c. Roof-Mounted Mechanicals
i.
Roof mounted mechanical equipment must be
screened or enclosed within a rooftop penthouse.
a). Roof-mounted photovoltaic (PV) devices are
exempt.
ii.
Mechanical equipment, screening, and rooftop
mechanical penthouses may exceed the maximum
height permitted for each building type by Special
Permit.
a). In addition to the review criteria for all Special
Permits specified in §15.2.1.e. Review
Criteria, the review board shall make findings
considering the following in its discretion to
approve or deny a special permit authorizing
mechanical equipment, screening, or rooftop
mechanical penthouse to exceed the maximum
height permitted for each building type:
i). Reserved
Table 4.2.13 Permitted Uses (continued)
Use Category
Specific Use
MR4
Accessory Uses
Home Occupations (as noted below)
--
Creative Studio
N
Hobby Kennel
N
Home-Based Business
N
Home Day Care
N
Home Office
P
Urban Agriculture (as noted below)
--
Apiculture
P
Aviculture
P
Commercial Farming
P
Residential Gardening
P
Vehicle Parking, Accessory
(except as follows)
P
Home Business Vehicle Parking
N
P - Permitted SP - Special Permit Required N - Not Permitted
(P or SP) - Permitted as specified per §4.2.13.b
173
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 5 (MR5)
173
SOMERVILLE ZONING ORDINANCE |
4. Mid-rise Districts
Mid-Rise 5 (MR5)
4.3.7. Apartment Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration (min/max)
15%
50%
Facade Build Out (min)
--
B
Upper Story Fenestration (min/max)
15%
50%
Primary Front
80%
Blank Wall (max)
20 ft
Secondary Front
65%
B
Floor plate (max)
20,000 sf
Use & Occupancy
Ground Story Elevation (min)
2 ft
Density Factor (min)
--
C
Story Height (min)
10 ft
Lot Area < 5,500 sf
1,500
D
Number of Stories (min/max)
3
5
Lot Area >= 5,500 sf
1,125
E
Step-Back, 5th Story (min)
10 ft
Net Zero Ready Building
850
F
Building Height, Feet (max)
62 ft
Outdoor Amenity Space (min)
1/DU
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
177
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 5 (MR5)
177
SOMERVILLE ZONING ORDINANCE |
4. Mid-rise Districts
Mid-Rise 5 (MR5)
4.3.8. General Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
50%
B
Floor plate (max)
20,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
14 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
3
5
Ground Story Entrance Spacing (max)
30 ft
F
Step-Back, 5th Story (min)
10 ft
Commercial Space Depth (min)
30 ft
G
Building Height, Feet (max)
66 ft
Density Factor (min)
--
Roof Type
Flat
Lot Area < 5,500 sf
1,500
Lot Area >= 5,500 sf
1,125
Net Zero Ready Building
850
Outdoor Amenity Space (min)
1/DU
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
181
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 5 (MR5)
181
SOMERVILLE ZONING ORDINANCE |
4. Mid-rise Districts
Mid-Rise 5 (MR5)
4.3.9. Commercial Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
70%
B
Floor plate (max)
20,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
14 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
3
5
Ground Story Entrance Spacing (max)
30 ft
F
Step-Back, 5th Story (min)
10 ft
Commercial Space Depth (min)
30 ft
G
Building Height, Feet (max)
70 ft
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
192
| SOMERVILLE ZONING ORDINANCE
12/12/2019
4. Mid-rise Districts
Mid-Rise 5 (MR5)
192
| SOMERVILLE ZONING ORDINANCE
4. Mid-rise Districts
Mid-Rise 5 (MR5)
Table 4.3.13 Permitted Uses (continued)
Use Category
Specific Use
MR5
Accessory Uses
Home Occupations (as noted below)
--
Creative Studio
N
Hobby Kennel
N
Home-Based Business
N
Home Day Care
N
Home Office
P
Urban Agriculture (as noted below)
--
Apiculture
P
Aviculture
P
Commercial Farming
P
Residential Gardening
P
Vehicle Parking, Accessory
(except as follows)
P
Home Business Vehicle Parking
N
P - Permitted SP - Special Permit Required N - Not Permitted
(P or SP) - Permitted as specified per §4.3.13.b
14. Development Standards
a. General
i.
Development is subject to the provisions of Article
10: Development Standards of this Ordinance.
Where the provisions of this section conflict with
those of Article 10, the provisions of Article 10
apply.
b. Signs
i.
A sign, individual numerals or letters, or a
nonelectrical nameplate identifying the property
address is required for all real property as follows:
a). Each ground story non-residential use must
identify the street address either on the
principal entrance door or above or beside the
principal entrance of the use.
b). All residential building types must identify the
street address either on the principal entrance
door, above or beside the principal entrance, or
on a mailbox.
ii.
Address signs must be made easily visible through
the use of colors or materials that contrast with the
background material they are attached to and must
be conspicuously located to provide visibility from
the thoroughfare that the building faces.
iii. Address signs must be twelve (12) inches in height
or less and may include the name of the occupant.
c. Roof-Mounted Mechanicals
i.
Roof mounted mechanical equipment must be
screened or enclosed within a rooftop penthouse.
a). Roof-mounted photovoltaic (PV) devices are
exempt.
ii.
Mechanical equipment, screening, and rooftop
mechanical penthouses may exceed the maximum
height permitted for each building type by Special
Permit.
a). In addition to the review criteria for all Special
Permits specified in §15.2.1.e. Review
Criteria, the review board shall make findings
considering the following in its discretion to
approve or deny a special permit authorizing
mechanical equipment, screening, or rooftop
mechanical penthouse to exceed the maximum
height permitted for each building type:
i). Reserved
201
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 6 (MR6)
201
4. Mid-rise Districts
Mid-Rise 6 (MR6)
4.4.7. Apartment Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration (min/max)
15%
50%
Facade Build Out
--
B
Upper Story Fenestration (min/max)
15%
50%
Primary Front
80%
Blank Wall (max)
20 ft
Secondary Front
65%
B
Floor plate (max)
25,000 sf
Use & Occupancy
Ground Story Elevation (min)
2 ft
Density Factor (min)
--
C
Story Height (min)
10 ft
Lot Area < 6,500 sf
1,125
D
Number of Stories (min/max)
3
6
Lot Area >= 6,500 sf
850
E
Step-Back, 5th - 6th Story (min)
10 ft
Net Zero Ready Building
650
F
Building Height, Feet
74 ft
Outdoor Amenity Space (min)
1/DU
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
205
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 6 (MR6)
205
4. Mid-rise Districts
Mid-Rise 6 (MR6)
4.4.8. General Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
50%
B
Floor plate (max)
30,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
18 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
3
6
Ground Story Entrance Spacing (max)
30 ft
F
Step-Back, 5th - 6th Story (min)
10 ft
Commercial Space Depth (min)
30 ft
G
Building Height, Feet (max)
80 ft
Density Factor (min)
--
Roof Type
Flat
Lot Area < 6,500 sf
1,125
Lot Area >= 6,500 sf
850
Net Zero Ready Building
650
Outdoor Amenity Space (min)
1/DU
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
209
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 6 (MR6)
209
4. Mid-rise Districts
Mid-Rise 6 (MR6)
4.4.9. Commercial Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Building Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15%
70%
B
Floor plate (max)
30,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
18 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
3
6
Ground Story Entrance Spacing (max)
30 ft
F
Step-Back, 5th - 6th Story (min)
10 ft
Commercial Space Depth (min)
30 ft
G
Building Height, Feet (max)
85 ft
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
213
SOMERVILLE ZONING ORDINANCE |
12/12/2019
4. Mid-rise Districts
Mid-Rise 6 (MR6)
213
4. Mid-rise Districts
Mid-Rise 6 (MR6)
4.4.10 Lab Building (continued)
c. Massing & Height
d. Uses & Features
Main Massing
Facade Composition
A
Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
80%
Secondary Facade (min/max)
15%
70%
Secondary Front
65%
B
Upper Story Fenestration (min/max)
15% 70%
B
Floor plate (max)
30,000 sf
Blank Wall (max)
20 ft
C
Ground Story Height (min)
18 ft
D
Upper Story Height (min)
10 ft
Use & Occupancy
E
Number of Stories (min/max)
3
6
Entrance Spacing (max)
30 ft
F
Step-Back, 5th - 6th Story (min)
10 ft
Commercial Space Depth (min)
30 ft
G
Building Height, Feet (max)
95 ft
Roof Type
Flat
Rooftop Mechanicals
Mechanical Equipment, Screening,
Penthouse Height (max)
15 ft
224
| SOMERVILLE ZONING ORDINANCE
12/12/2019
4. Mid-rise Districts
Mid-Rise 6 (MR6)
4. Mid-rise Districts
Mid-Rise 6 (MR6)
15. Development Standards
a. General
i.
Development is subject to the provisions of Article
10: Development Standards of this Ordinance.
Where the provisions of this section conflict with
those of Article 10, the provisions of Article 10
apply.
b. Signs
i.
A sign, individual numerals or letters, or a
nonelectrical nameplate identifying the property
address is required for all real property as follows:
a). Each ground story non-residential use must
identify the street address either on the
principal entrance door or above or beside the
principal entrance of the use.
b). All residential building types must identify the
street address either on the principal entrance
door, above or beside the principal entrance, or
on a mailbox.
ii.
Address signs must be made easily visible through
the use of colors or materials that contrast with the
background material they are attached to and must
be conspicuously located to provide visibility from
the thoroughfare that the building faces.
iii. Address signs must be twelve (12) inches in height
or less and may include the name of the occupant.
c. Roof-Mounted Mechanicals
i.
Roof mounted mechanical equipment must be
screened or enclosed within a rooftop penthouse.
a). Roof-mounted photovoltaic (PV) devices are
exempt.
ii.
Mechanical equipment, screening, and rooftop
mechanical penthouses may exceed the maximum
height permitted for each building type by Special
Permit.
a). In addition to the review criteria for all Special
Permits specified in §15.2.1.e. Review
Criteria, the review board shall make findings
considering the following in its discretion to
approve or deny a special permit authorizing
mechanical equipment, screening, or rooftop
mechanical penthouse to exceed the maximum
height permitted for each building type:
i). Reserved
Table 4.4.14 Permitted Uses (continued)
Use Category
Specific Use
MR6
Accessory Uses
Home Occupations (as noted below)
--
Creative Studio
N
Hobby Kennel
N
Home-Based Business
N
Home Day Care
N
Home Office
P
Urban Agriculture (as noted below)
--
Apiculture
P
Aviculture
P
Commercial Farming
P
Residential Gardening
P
P - Permitted SP - Special Permit Required N - Not Permitted
(P or SP) - Permitted as specified per §4.4.14.b
5. High-rise Districts
High-Rise (HR)
259
SOMERVILLE ZONING ORDINANCE |
12/12/2019
f.
Vents, exhausts, and other utility features on building
facades should be architecturally integrated into
the design of the building and should be located to
minimize adverse effects on pedestrian comfort along
sidewalks and within open spaces.
g. Buildings at terminated vistas should be articulated with
design features that function as focal points.
h. Fenestration glazing should be inset from the plane of
exterior wall surfaces.
i.
Ribbon windows should be avoided.
j.
Monotonous and repetitive storefront or lobby
systems, awnings, canopies, sign types, colors, or
designs should be avoided.
k. Storefronts and lobby entrances should include
awnings or canopies to provide weather protection
for pedestrians and reduce glare for storefront display
areas. Awnings should be open-ended and operable.
l.
Lobby entrances for upper story uses should be
optimally located, well defined, clearly visible, and
separate from the entrance for other ground story uses.
m. Lobbies should be limited in both width and total area
to preserve floor space and frontage for other ground
story uses. Buildings should use any combination of
facade articulation, a double-height ceiling, a distinctive
doorway, a change in wall material, a change in paving
material within the frontage area, or some other
architectural element(s) to make lobbies visual and
materially distinctive.
n. The selection of materials, fenestration, and
ornamentation should result in a consistent and
harmonious composition that appears as a unified
whole rather than a collection of unrelated parts.
o. The type and color of materials should be kept to a
minimum, preferably three (3) or fewer.
p. Two (2) or more wall materials should be combined
only one above the other, except for bay windows.
q. Wall materials appearing heavier in weight should be
used below wall materials appearing lighter in weight
(wood and metal above brick, and all three above
stone)
r.
Horizontal or vertical board siding or shingles,
regardless of material, should be avoided.
s. Architectural details and finish materials for the base
of a building should be constructed of architectural
concrete or pre-cast cementitious panels, natural
or cast stone, heavy gauge metal panels, glazed or
unglazed architectural terracotta, or brick.
t.
Exterior Insulation and Finish Systems (EIFS) should be
avoided.
u. Rooftop mechanical penthouses and screening should
be integrated into the overall building massing and
architectural design of the building, appearing as an
extension of the stories below or differeniated as the
top of the horizontal triparite division.
v.
Rooftop mechanical penthouses and screening should
be located to minimize adverse environmental impacts
on civic spaces, sidewalks, and abutting lots.
w. Vents, stacks, railings and other components of
mechanical equipment required to be outdoors or to
project above a penthouse should be limited in height
and located toward the center of the roof to every
extent practicable.
5. High-rise Districts
High-Rise (HR)
262
| SOMERVILLE ZONING ORDINANCE
12/12/2019
16. Development Standards
a. General
i.
Development is subject to Article 10: Development
Standards of this Ordinance. Where the provisions
of this section conflict with those of Article 10, the
provisions of Article 10 apply.
b. Signs
i.
A sign, individual numerals or letters, or a
nonelectrical nameplate identifying the property
address is required for all real property as follows:
a). Each ground story non-residential use must
identify the street address either on the
principal entrance door or above or beside the
principal entrance of the use.
b). All residential building types must identify the
street address either on the principal entrance
door, above or beside the principal entrance, or
on a mailbox.
ii.
Address signs must be made easily visible through
the use of colors or materials that contrast with the
background material they are attached to and must
be conspicuously located to provide visibility from
the thoroughfare that the building faces.
iii. Address signs must be twelve (12) inches in height
or less and may include the name of the occupant.
c. Roof-Mounted Mechanicals
i.
Roof mounted mechanical equipment must be
screened or enclosed within a rooftop penthouse.
a). Roof-mounted photovoltaic (PV) devices are
exempt.
Table 5.1.15 Permitted Uses (continued)
Use Category
Specific Use
HR
Accessory Uses
Home Occupations (as noted below)
--
Home Office
P
Urban Agriculture (as noted below)
--
Apiculture
P
Aviculture
P
Commercial Farming
P
Residential Gardening
P
P - Permitted SP - Special Permit Required N - Not Permitted
(P or SP) - Permitted as specified per §5.1.15.b
6.0 Commercial Districts
Commercial Core (CC)
291
SOMERVILLE ZONING ORDINANCE |
08/22/21
6.2.7. Commercial Building (continued)
c.
Height & Massing
d.
Uses & Features
Main Mass
Facade Composition
A
Width (max)
200 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Frontage
80%
Secondary Facade (min/max)
15%
70%
Secondary Frontage
65%
B
Upper Story Fenestration (min/max)
15%
70%
Floor plate (max)
30,000 sf
Blank Wall (max)
20 ft
B
Ground Story Height (min)
18 ft
C
Upper Story Height (min)
10 ft
Use & Occupancy
D
Number of Stories (min)
3 stories
Entrance Spacing (max)
30 ft
E
Number of Stories (max)
Varies by Map
Designation
Commercial Space Depth (min)
30 ft
F
Building Height, Feet (max)
--
3 Story
50 ft
Rooftop Mechanicals
4 Story
55 ft
Mechanical Equipment, Screening,
Penthouse Height (max)
--
5 Story
70 ft
3 - 4 Story
10 ft
7 Story
100 ft
5 - 10 Story
15 ft
10 Story
150 ft
Roof Type
Flat
6.0 Commercial Districts
Commercial Core (CC)
295
SOMERVILLE ZONING ORDINANCE |
08/22/21
6.2.8. Lab Building (continued)
c. Height & Massing
d. Uses & Features
Main Mass
Facade Composition
A
Width (max)
240 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Frontage
80%
Secondary Facade (min/max)
15%
70%
Secondary Frontage
65%
B
Upper Story Fenestration (min/max)
15%
70%
Floor plate
35,000 sf
Blank Wall (max)
20 ft
B
Ground Story Height (min)
18 ft
C
Upper Story Height (min)
10 ft
Use & Occupancy
D
Number of Stories (min)
3 stories
Entrance Spacing (max)
30 ft
E
Number of Stories (max)
Varies by Map
Designation
Commercial Space Depth (min)
30 ft
F
Building Height, Feet (max)
--
3 Story
50 ft
Rooftop Mechanicals
4 Story
65 ft
Mechanical Equipment, Screening,
Penthouse Height (max)
--
5 Story
80 ft
3 - 4 Story
10 ft
7 Story
110 ft
5 - 10 Story
15 ft
10 Story
155 ft
Roof Type
Flat
6.0 Commercial Districts
Commercial Core (CC)
299
SOMERVILLE ZONING ORDINANCE |
08/22/21
6.2.9. Commercial Block Building (continued)
c. Massing & Height
d. Uses & Features
Main Mass
Facade Composition
A
Building Width (max)
500 ft
A
Ground Story Fenestration
--
Facade Build Out (min)
--
Primary Facade (min)
70%
Primary Front
100%
Secondary Facade (min/max)
15%
70%
Secondary Front
100%
B
Upper Story Fenestration (min/max)
15%
70%
Floor plate (max)
--
Blank Wall (max)
20 ft
Podium
n/a
Tower(s)
30,000 sf
Use & Occupancy
B
Ground Story Height (min)
18 ft
Ground Story Entrance Spacing (max)
30 ft
C
Upper Story Height (min)
10 ft
Commercial Space Depth (min)
30 ft
D
Number of Stories (min)
3 stories
Number of Stories (max)
--
Rooftop Mechanicals
E
Podium
6 stories
Mechanical Equipment, Screening,
Penthouse Height (max)
--
F
Tower(s)
10 stories
3 - 4 Story
10 ft
G
Building Height (min)
--
5 - 10 Story
15 ft
Podium
80 ft
Tower
140 ft
Roof Type
Flat
6.0 Commercial Districts
Commercial Core (CC)
309
SOMERVILLE ZONING ORDINANCE |
08/22/21
14. Development Standards
a. General
i.
Development is subject to the provisions of Article
10 Site Development of this Ordinance. Where the
provisions of this section conflict with those of
Article 10, the provisions of Article 10 apply.
b. Signs
i.
A sign, individual numerals or letters, or a
nonelectrical nameplate identifying the property
address is required for all real property as follows:
a). Each ground story non-residential use must
identify the street address either on the
principal entrance door or above or beside the
principal entrance of the use.
b). All residential building types must identify the
street address either on the principal entrance
door, above or beside the principal entrance, or
on a mailbox.
ii.
Address signs must be made easily visible through
the use of colors or materials that contrast with the
background material they are attached to and must
be conspicuously located to provide visibility from
the thoroughfare that the building faces.
iii. Address signs must be twelve (12) inches in height
or less and may include the name of the occupant.
c. Roof-Mounted Mechanicals
i.
Roof mounted mechanical equipment must be
screened or enclosed within a rooftop penthouse.
a). Roof-mounted photovoltaic (PV) devices are
exempt.
ii.
Mechanical equipment, screening, and rooftop
mechanical penthouses may exceed the maximum
height permitted for each building type by Special
Permit.
a). In addition to the review criteria for all Special
Permits specified in §15.2.1.e. Review
Criteria, the review board shall make findings
considering the following in its discretion to
approve or deny a special permit authorizing
mechanical equipment, screening, or rooftop
mechanical penthouse to exceed the maximum
height permitted for each building type:
i). Reserved
15. Parking & Mobility
a. General
i.
Development is subject to the provisions of Article
11: Parking & Mobility of this Ordinance. Where
the provisions of this section conflict with those of
Article 11, the provisions of Article 11 apply.
ii.
Vehicular parking must be provided as specified on
Table 6.2.15, except as follows:
a). Non-residential uses with five thousand (5,000)
square feet or less of gross leasable floor area
are exempt from any minimum requirements
of Table 6.2.15.
b). Any change in use within a non-residential
structure constructed before the effective date
of this Ordinance, provided that the change
is to a permitted use, is exempt from any
minimum requirements of Table 6.2.15.
iii. There are no parking requirements for accessory
uses.
iv. Motor vehicle parking spaces may be shared
between uses on the same lot and buildings on
the same block in accordance with §11.3 Shared
Parking.
b. Type
i.
Motor vehicle parking may be provided as above
ground structured parking or underground
structured parking. Surface parking is prohibited.
c. Driveways
i.
New driveways require a permit from the City
Engineer.
ii.
Driveways must be compliant with all City
Ordinances and constructed in accordance
with all standards established by relevant City
Departments.
iii. Driveways are not permitted in the frontage area
between a building and the front lot line.
iv. Driveways may be no wider than twenty four (24)
feet in the frontage area of a lot.
v.
Driveways may provide access in whole or in part
on or across an abutting lot(s), provided that an
access easement exists between all property owners.
d. Parking Design
i.
The design of all parking is subject to §11.1 Bicycle
Parking and §11.2 Motor Vehicle Parking of this
Ordinance.
e. Parking Location
i.
Required vehicular parking, excluding any required
handicapped parking, may be provided on a
contiguous lot under the same ownership as the
lot that the parking will serve as follows:
a). Pedestrian access to off-site vehicular parking
must be via a paved sidewalk or walkway.
b). A lease, recorded covenant, or other
comparable legal instrument guaranteeing long
458
| SOMERVILLE ZONING ORDINANCE
08/22/21
10. Development Standards
Screening
10.8
SCREENING
1. Applicability
a. Real property within the Commercial Industry district is
exempt from the provision of this Section.
2. Loading Facilities
a. Outdoor loading facilities, including all docks and areas
used for the storage and staging of materials must
be screened from view by a wall or fully closed fence
between six (6) and twelve (12) feet in height, as
necessary to sufficiently screen delivery vehicles, and
constructed of materials that are compatible with the
principal building in terms of texture, quality, and color.
b. Exterior entrances and access to loading facilities
that are fully enclosed within a building must have an
opaque, self closing door constructed of materials that
are compatible with the principal building in terms of
texture, quality, and color.
c. Loading facility doors are only permitted to be opened
during loading and unloading activities.
3. Service Areas
a. Trash collection, trash compaction, recycling collection
and other similar service areas must be fully enclosed
within a building or located to the side or rear of the
buildings.
b. Exterior entrances and access to service areas that
are fully enclosed within a building must have an
opaque, self closing door constructed of materials that
are compatible with the principal building in terms of
texture, quality, and color.
c. Outdoor service areas that are visible from a public
thoroughfare (excluding an alley), civic space, or abutting
properties in the NR zoning district must be fully
screened by a wall or fully closed fence at least six
(6) feet in height with self-closing access doors and
constructed of materials that are compatible with the
principal building in terms of texture, quality, and color.
4. Mechanical Equipment
a. Roof-Mounted
i.
Mechanical equipment, except roof-mounted
sustainable energy systems, and elevator/stairwell
penthouses must be set back at least ten (10) feet
from the edge of the exterior wall of a building.
ii.
New buildings must provide a parapet wall or other
architectural element constructed of materials
that are compatible with the principal building in
terms of texture, quality, and color that screens the
visibility of roof-mounted mechanical equipment
from any a public thoroughfare (excluding an alley)
or civic space.
b. Wall-Mounted
i.
Mechanical equipment is not permitted on any
facade.
ii.
Mechanical equipment on any surface that is
visible from a public thoroughfare (excluding
an alley) or civic space must be screened by
landscaping or an opaque screen constructed of
materials that are compatible with the principal
building in terms of texture, quality, and color.
c. Ground-Mounted
i.
Mechanical equipment that is visible from a public
thoroughfare (excluding an alley) or civic space must
be screened by landscaping, a fence, or a wall
constructed of materials that are compatible with
the principal building in terms of texture, quality,
and color.
ii.
Screening must be of a height equal to or greater
than the height of the mechanical equipment being
screened.