Matters ▸ Attachment
3.1.13 & 3.2.12 Building Components Amendments — File 26-0851
Somerville Zoning Ordinance
1
3.1.13 Building Components
a.
Building components are accessory elements attached to the main massing of a principal building.
b.
Building components are permitted as specified on Table 3.1.13.
c.
Building components that are not identified on Table 3.1.13 are prohibited.
d.
Unless otherwise specified, building components may attach to other building components to create
assemblies of components.
Table 3.1.13 Building Components
Cottage
Detached
House
Semi-
Detached
House
Duplex
Detached
Triple
Decker
Backyard
Cottage
Entry Canopy
P
P
P
P
P
P
Stoop
P
P
P
P
P
P
Portico
P
P
P
P
P
P
Projecting Porch
P
P
P
P
P
P
Engaged Porch
P
P
P
P
N
N
Bay
P
P
P
P
P
N
Gable Dormer
P
P
P
P
N
PN
Shed Dormer
P
P
P
P
N
PN
Cross Gable
P
P
P
P
N
P
Projecting Gable
P
P
P
P
N
N
Side Wing
P
P
P
P
N
N
Rear Addition
P
P
P
P
N
N
P - Permitted • SP - Special Permit Required • N - Not Permitted
Somerville Zoning Ordinance
2
k. Gable Dormer
i. A gable dormer is a window space with a
gable, hip, or arched roof that projects
perpendicularly from a pitched roof. Dormer
windows provide light to the habitable space
of a half-story.Gable dormers provide light and
additional habitable space to a half-story.
l. Shed Dormer
i. A shed dormer is window space with a shed
roof that projects perpendicularly from a
pitched roof. Shed dormers provide light and
additional habitable space to a half-story.
Dimensions
Dimensions
Face Width
(max)Fenestration (min)
Window(s) width
+18 in15%
Face Width
(max)Fenestration (min)
Window(s) width
+36 in15%
Side Wall Setback (min)
–
Side Wall Setback (min)
–
Roof with eave
0 ft
Roof with eave
0 ft
Roof without eave
1 ft
Roof without eave
1 ft
Facade & Rear Wall Setback
3 ft
Facade & Rear Wall Setback
3 ft
Side Facing Dormer
2 ft
Side Facing Dormer
2 ft
Ridge Setback (min)
1 ft
Ridge Setback (min)
1 ft
Dormer Separation (min)
50% of width
Dormer Separation (min)
50% of width
ii. Standards
ii. Standards
Somerville Zoning Ordinance
3
a). The face wall of aA gable dormer may
not project beyond the exterior wall of
the building and may not interrupt the
eave of the roof.
b). A gable dormer may not extend above
the roof ridge line.
c). Gable dormers may interrupt the eave of
an existing roof only if the finished floor
of the half story is two (2) or more feet
below the eave.
b).d). Gable dormers may project from a
cross gable or be combined with a shed
dormer(s) to create a Nantucket dormer.
c). The cumulative width of a single,
multiple, or attached combinations of
dormers may equal up to fifty percent
(50%) of the eave/ridge length of the
roof.
d).e). Flat roofs are prohibited.
a). The face wall of aA shed dormer may not
project beyond the exterior wall of the
building and may not interrupt the eave of
the roof.
b). A she dormer may not extend above the
roof ridge line.
c). Shed dormers may interrupt the eave of an
existing roof only if the finished floor of the
half story is two (2) or more feet below the
eave.
b).d).
Shed dormers may project from a
cross gable or be combined with a dormer
window(s) to create a Nantucket dormer.
c). The cumulative width of a single, multiple,
or attached combinations of dormers may
equal up to fifty percent (50%) of the
eave/ridge length of the roof.
d).e).
Flat roofs are prohibited.
Somerville Zoning Ordinance
Date Printed: 7/12/2023
1
k. Balcony
i. A balcony is a front, side, or rear facing upper
story platform enclosed by a wall, railing, or
balustrade and accessed from an entrance of a
building.
l. Gable Dormer
i. A gable dormer is a window space with a
gable, hip, or arched roof that projects
perpendicularly from a pitched roof. Dormer
windows provide light to the habitable space
of a half-story.Gable dormers provide light and
additional habitable space to a half-story.
Dimensions
Dimensions
Width (min)
4 ft
Width (max)Fenestration (min)
Window(s)
width +18
in15%
Depth (min)
3 ft
Side Wall Setback (max)
–
Setback Encroachment (max)
–
Roof with eave
0 ft
Front
100%
Roof without eave
1 ft
Side
0 ft
Facade & Rear Wall Setback (min)
3 ft
Side Facing Dormer
2 ft
Rear
0 ft
Ridge Setback (min)
1 ft
ii. Standards
a). Balconies may be recessed, projecting, a
combination of the two, or terraced as part
of the roof of a portico, porch, or bay.
b). Balconies that project over any public
sidewalk require compliance with all City
Dormer Separation (min)
50% of
width
ii. Standards
a). The face wall of aA gable dormer may not
project beyond the exterior wall of the
buildingand may not interrupt the eave of
Somerville Zoning Ordinance
Date Printed: 7/12/2023
2
Ordinances.
c). Side and rear balconies abutting the NR
district must include sight-obscuring visual
screening so that it is at least fifty percent
(50%) opaque.
the roof.
b). A gable dormer may not extend above the
roof ridge line.
c). Gable dormers may interrupt the eave of
an existing roof only if the finished floor of
the half story is two (2) or more feet below
the eave.
b).d).
Gable dormers may project from a
cross gable or be combined with a shed
dormer(s) to create a Nantucket dormer.
c). The cumulative width of a single, multiple,
or attached combinations of dormers may
equal up to fifty percent (50%) of the
eave/ridge length of the roof.
d).e).
Flat roofs are prohibited.
m. Shed Dormer
i. A shed dormer is window space with a shed
roof that projects perpendicularly from a
pitched roof. Shed dormers provide light and
additional habitable space to a half-story.
n. Cross Gable
i. A cross gable is a sloped roof that projects
perpendicularly from the main roof of a
building to significantly increase the habitable
space of a half-story.
Dimensions
Dimensions
Width (max)Fenestration (min)
Window(s)
width +36
in15%
Width (max)
50% of the
eave length
of the main
roof
Side Wall Setback (min)
–
ii. Standards
a). The ridge and eave of the cross gable must
Roof with eave
0 ft
Somerville Zoning Ordinance
Date Printed: 7/12/2023
3
Roof without eave
1 ft
be structurally integrated into the ridge
and eave of the main roof.
b). Cross gables never have cheek walls.
Façade & Rear Wall Setback (min)
3 ft
Side Facing Dormer
2 ft
Ridge Setback (min)
1 ft
Dormer Separation (min)
50% of
width
ii. Standards
a). The face wall of aA shed dormer may not
project beyond the exterior wall of the
building and may not interrupt the eave of
the roof.
b). A shed dormer may not extend above the
roof ridge line.
c). Shed dormers may interrupt the eave of an
existing roof only if the finished floor of the
half-story is two (2) or more feet below the
eave.
b).d).
Shed dormers may project from a
cross gable or be combined with a dormer
window(s) to create a Nantucket dormer.
c). The cumulative width of a single, multiple,
or attached combinations of dormers may
equal up to fifty percent (50%) of the
eave/ridge length of the roof.
d).e).
Flat roofs are prohibited.