Matters ▸ Attachment
Somerville Fire Final Report — File 190167
Evaluation and Strategic
Plan for the Fire Department
SOMERVILLE, MASSACHUSETTS
July 2010
TABLE OF CONTENTS
Page Number
1.
INTRODUCTION AND EXECUTIVE SUMMARY
1
2.
ORGANIZATIONAL STRUCTURE AND MANAGEMENT SYSTEMS
8
3.
ASSESSMENT OF FIRE ALARM
48
4.
ASSESSMENT OF FIRE DEPARTMENT
SUPPRESSION OPERATIONS
61
5.
ASSESSMENT OF FIRE PREVENTION AND PUBLIC EDUCATION
78
Matrix Consulting Group
1.
INTRODUCTION AND EXECUTIVE SUMMARY
The Matrix Consulting Group was retained by the City of Somerville to develop
an Evaluation and Strategic Plan for the Fire Department, which included an extensive
review of organization, operations, and management. In reaching the concluding point
of the study, the project team has assembled this report, which summarizes our
findings, conclusions and recommendations, where appropriate. This study was
conducted with cooperation and assistance of City of Somerville – SomerStat –
personnel in conjunction with an external consultant from the Matrix Consulting Group.
The Matrix Consulting Group is a national management consulting firm dedicated to
assessing public safety service delivery in cities and other jurisdictions.
In this study of the Somerville Fire Department (SFD), the project team utilized a
wide variety of data collection and analytical techniques. The project team conducted
the following data collection and analytical activities:
•
The project team began an intensive process of interviewing personnel in every
Fire Department Division and collecting a wide variety of data designed to
document workloads and service levels.
•
Staff at every rank and in every function were interviewed either one on one or in
small groups. This included personnel in operations, support and fire alarm
functions.
•
Additionally, the project team from SomerStat and the Matrix Consulting Group
interviewed representatives of the bargaining unit’s executive board as part of
this process.
•
The project team also compared organizational structure, staffing levels, as well
as certain operational and service delivery areas against other comparable fire /
rescue departments.
•
The Fire Department was compared to a series of best management practices
developed by the Matrix Consulting Group. This process was used to identify
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 2
issues on a wide range of topics in the Fire Department, as well as a process by
which positive aspects of the Fire Department could be identified. These are
included in each chapter.
•
The project team collected detailed workload statistics for the primary functional
areas, including calls for service from the computer aided dispatch / records
management system, budget documents and monthly statistical reports.
Throughout the performance audit process, the project team reviewed interim
deliverables, including the findings and issues, with the project steering committee,
consisting of both SFD and City management.
2.
EXECUTIVE SUMMARY
The project team has prepared a summary of the key findings, conclusions and
recommendations to be found in this final report. The primary findings and
recommendations identified in the Final Report are summarized in the exhibit which
follows:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 3
Report
Section /
Page
Finding
Recommendation
Fiscal
Impact
Responsible
Parties
Recommended
Priority
Page 23
The organizational structure of the Fire
Department only provides for the Chief to
be out of the bargaining unit. The project
team explored a number of options.
The Fire Department and the
Mayor’s Office should work to
convert a single Deputy Chief
position to that of a non-union
Assistant Chief.
$14,500
Chief, Mayor’s
Office
Medium
Page 27
The Fire Department is operating without
many key management documents in
place, including: no long range planning,
no performance measures, no annual
work plan, little review time dedicated to
assessing basic performance, etc.
The Fire Chief must take
actions, in conjunction with the
command staff, to improve the
overall management systems
of the Fire Department.
Without these critical
documents, the Department
will continue to react to
situations rather than
proactively address them.
None
Chief, Command
Staff
High
Page 27
There are no regular meetings of the
management team of the Fire
Department.
The Fire Department command
staff should hold regular, at
least monthly, meetings to
review issues, discuss
assignments, etc.
$10,000
Chief
High
Page 37
The Fire Department needs to have up to
date policies and procedures in order to
be effective.
Policies and procedures need
to be comprehensive and to be
modern in their scope and
content.
None (Staff)
Chief, Command
Staff
Highest
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 4
Report
Section /
Page
Finding
Recommendation
Fiscal
Impact
Responsible
Parties
Recommended
Priority
Page 42
Training in the Fire Department is not
well organized and suffers from lack of
involvement by company officers.
Target development of training
by company officers,
distributed by the Training
office. Focus on on-duty
training at the company level,
at least two hours daily.
Additional focus on
performance based training.
Provide some overtime funding
for multi-company drills.
$50,000 for
training overtime
Chief, Mayor’s
Office,
Command Staff,
Company
Officers
Medium
Medium
Page 46
The Fire Department does not have an
analytical position dedicated to
supporting the Chief and the command
staff in identifying data sources or to
provide day to day analytical support.
Add a management analyst
position to the Fire
Department. The training for
such a person should be
similar to that which is typically
found in a crime analyst in the
police department.
$80,000
Chief, Mayor’s
Office, Human
Resources
Medium
Page 50 /
Page 55
Staffing in Fire Alarm, at two personnel is
necessary to handle major incidents.
However, it is also a very inefficient level
of staffing given total workloads.
Changing the work schedule to a 4/2
plan would allow for a reduction of one
position (3 per shift).
Serious consideration should
be given to consolidating
dispatch within the City of
Somerville or between the City
and neighboring communities.
The City should work to
bargain a 4/2 schedule and
reduce the one position.
($500,000)
($100,000)
Chief, Mayor’s
Office
High
Page 58
As with general Fire operations, there are
no performance measures in place for
the Fire Alarm unit.
Develop specific performance
measures for Fire Alarm.
Monitor those measures on a
daily / weekly / monthly basis.
None
Chief, Command
Staff, Chief
Operator in Fire
Alarm
High
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 5
Report
Section /
Page
Finding
Recommendation
Fiscal
Impact
Responsible
Parties
Recommended
Priority
Page 71
The Fire Department does not have
performance measures in place for Fire
Suppression.
Develop specific performance
measures for Fire
Suppression. Monitor those
measures on a daily / weekly /
monthly basis.
None
Chief, Command
Staff
High
Page 73
Fire Stations are well situated to provide
excellent coverage of the City of
Somerville.
Consider pursuing a new Fire
Station in the Assembly
Square development area.
This would provide for
enhanced multi-unit response
into that area.
Unknown
Chief, Mayor’s
Office, Planning
Medium
Page 74
Visual inspection of the City’s fire
stations by the project team indicate that
there are a number of potentially
significant issues.
The City should retain a
consulting engineer in order to
obtain an evaluation of
structural and systems issues
in the Fire Stations.
$50,000
Chief, Mayor’s
Office
Medium
Page 75
Currently, Fire Department vehicle /
apparatus maintenance is performed by
a single Mechanic in a very small
maintenance area.
Move Fire Maintenance to a
facility where there are other
City heavy equipment
maintenance personnel
assigned. Continue to
maintain a dedicated Fire
Mechanic, with assistance from
other heavy vehicle
mechanics. In the interim,
authorize use of some
Firefighter or temporary
mechanic time to support the
Mechanic during heavy
maintenance tasks.
Unknown
Chief, Mayor’s
Office
High
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 6
Report
Section /
Page
Finding
Recommendation
Fiscal
Impact
Responsible
Parties
Recommended
Priority
Page 80
Fire Prevention is located in office space
that is inadequate for most of its needs.
Seek alternative office space
for Fire Prevention. This space
should provide for private
offices, storage space, space
for reviewing plans, etc.
None (City
owned space)
Chief, Mayor’s
Office
Medium
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 7
At the conclusion of this study, the Fire Department, under the direction of the
Office of the Mayor, should assess which recommendations should be implemented.
This process should include the following:
•
Internal assessment of each recommendation.
•
Determine if funding is available to implement the recommendation.
•
Develop an internal mechanisms for tracking the recommendations to ensure
that they are completed within targeted time frames.
The overall benefits from implementing the recommendations encapsulated in
this report should include the following:
•
Improved operational management and service delivery.
•
Improved risk management for the City, the Fire Department and its employees.
•
Enhanced professionalism and management of the Fire Department.
The next chapter of this report focuses on management and organizational
issues that span the scope of the Department’s operations.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 8
2.
ORGANIZATIONAL STRUCTURE AND
MANAGEMENT SYSTEMS
This first analytical chapter of the report focuses on key organizational structure
and management systems issues facing the Fire Department. As is the case with each
chapter, the first section provides a comparison of the Fire Department to a series of
best management practices.
1.
THE
FIRE
DEPARTMENT
FACES
A
NUMBER
OF
ISSUES
AND
OPPORTUNITIES RELATED TO ORGANIZATIONAL STRUCTURE AND
MANAGEMENT SYSTEMS.
The Matrix Consulting Group applied a series of “best management practices” to
each area of the Fire Department. These are provided, below, summarizing those
issues that impact the management and organizational structure of the Somerville Fire
Department. Others are presented in later sections of the report.
Performance Target
Strengths
Potential Improvements
ORGANIZATION AND MANAGEMENT
The Department has a defined
chain of command with clear lines
of authority. The organization
chart is available to all members
of the Department.
!
The Department has a written
vision and mission statement.
The statement is available to all
members of the Department.
!
The Department has a written
long range plan. The long-range
plan is available to all members of
the Department.
!
The management team holds
regular meetings with written
agendas and minutes.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 9
Performance Target
Strengths
Potential Improvements
The Department has a
management accountability
system that identifies group
performance goals.
!
The Department is Accredited or
is seeking Accreditation.
!
The Department has written
policies and procedures that are
reviewed and updated regularly.
!
The Department has an
automated system for managing
and distributing its policies and
procedures.
!
Critical policies meet national
standards and recognize national
and local legal requirements.
!
Staff inspections are conducted
based on need and a defined
schedule that ensures all
components are inspected
annually.
!
The organization has grouped like
functions together to support the
organization’s mission and goals.
!
The organizational structure
supports equivalent spans of
control for similar levels of
management.
!
Personnel of like rank have
similar levels of responsibility.
!
The organizational structure
supports goals of one manager
per function and ensures that
staff report to a single manager.
!
The Department has a public
information program.
!
ANALYSIS AND PLANNING
The Department has a planning
and analysis function.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 10
Performance Target
Strengths
Potential Improvements
The Department produces an
annual improvement and
associated project plan.
!
The Department produces an
annual report.
!
The Department maintains a web
site to distribute information to its
members and to the general
public.
!
Planners have access to
automated tools to abstract and
analyze data from the
Department’s automated records
system.
!
The Department has a computer
aided dispatch (CAD) system that
supports Fire and EMS
operations.
!
The Department has an
automated records management
system (RMS) that supports fire
suppression, emergency medical
and fire prevention reporting
requirements.
!
The Department routinely
monitors and analyzes CAD and
RMS data to ensure that the data
is accurate.
!
The Department routinely
analyzes and monitors
emergency vehicle reflex and
travel times to identify problems.
!
PERSONNEL MANAGEMENT
The Department has a personnel
manager.
!
The Department has a written
personnel manual.
!
The Department has an
automated personnel
management system.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 11
Performance Target
Strengths
Potential Improvements
The Department conducts annual
evaluations of all personnel.
!
The Department’s hiring process
is compliant with state and federal
guidelines.
!
The Department has a health and
safety program for its employees
!
Background testing of new hires
conducted before a job offer is
made.
!
STATIONS, APPARATUS AND EQUIPMENT
The Department has a written
long range plan for the
replacement and repair of its
facilities.
!
The Department’s facilities meet
all local, state and federal health
and safety standards.
!
The Department’s facilities are
inspected annually to ensure that
they meet all building
maintenance, health and safety
standards.
!
All facilities are equipped with
automatic sprinkler and
fire/smoke detection systems.
!
All facilities housing vehicles are
equipped with automatic exhaust
ejection systems.
!
The Department’s facility
replacement and renovation plan
has been budgeted in the
jurisdiction’s long-range capital
plan.
!
The Department has a written
long-range fleet replacement plan
that specifies the life cycle for
apparatus (i.e., Engines, Ladders,
Rescues, Ambulances).
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 12
Performance Target
Strengths
Potential Improvements
The Department’s vehicle
replacement plan is based on the
following criteria:
Cars – 120,000 miles
Ambulances -120,000 miles
Command vehicles- 120,000
miles
Engines, ladders and heavy
rescues - 12 - 15 years.
!
The Department’s fleet
replacement plan has been
funded in the jurisdiction’s long-
range capital plan.
!
The Department has an
automated fleet management
system to monitor equipment
utilization and repair histories,
labor distribution, downtime and
costs.
!
The Department’s fleet
management program schedules
preventive maintenance and
inspections for all vehicles.
!
The Department’s apparatus
repair facility has the proper
equipment to handle large and
specialized apparatus.
!
The Department’s emergency
vehicle mechanics are
emergency vehicle technician
(EVT) certified.
!
The Department conducts annual
pump and ladder tests and all of
the in-service apparatus is
certified.
!
The Department has sufficient
equipped reserve apparatus.
1 reserve engine per 4 engines
1 reserve ladder per 4 ladders
1 reserve ambulance per 4
ambulances
!
The Department routinely
disposes of surplus apparatus.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 13
Performance Target
Strengths
Potential Improvements
The Department’s turnout gear
and SCBA’s meet national
standards.
!
The Department has a written
long-range replacement plan for
turnout gear and SCBA’s.
!
The Department has an
automated system to monitor its
turnout gear and SCBA’s
!
TRAINING
The Department has a training
budget to provide both in-house
and outside training for its fire and
EMS personnel.
!
The training officer creates
monthly and weekly training
schedules for both fire and EMS
instruction.
!
The fire and EMS training
programs are designed to meet
state re-certification
requirements.
!
The Department has an
automated system to track
training attendance and
certifications.
!
Training instructors meet NFPA
and EMS training certification
requirements.
!
Training instructors are required
to prepare and submit lesson
plans to the Department’s training
officer for review and approval.
!
The Department has adopted
NFPA Firefighter I, II and III
requirements for Firefighters.
!
Fire training evolutions are based
on NFPA 1410.
!
Department conducts monthly
multi-company drills on both the
day and night shifts.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 14
Performance Target
Strengths
Potential Improvements
Company officers conduct
training activities on both the day
and the night shift.
!
Company officers and senior
EMS personnel are required to
document the completion of all
scheduled training and to update
the records of individuals who
attended the training.
!
Chief officers and company
officers and senior EMS
personnel are expected to
provide training classes.
!
The
Department
conducts
a
periodic
training
needs
assessment to determine what
training to offer.
!
The Department closely monitors
EMS recertification requirements.
!
The following paragraphs offer a summary of the key issues identified, in the
preceding exhibit:
•
There are no long range plans in place within the Fire Department.
•
The Fire Department does not operate under a set of performance measures
against which management or operations can be assessed.
•
There is no routine monitoring of basic performance measures such as unit reflex
time (the time it takes to react to a newly dispatch alarm until the vehicle is
moving) or vehicle drive times (from the time a unit leaves the station until it
arrives at the scene).
•
The Fire Department is not accredited nor have any steps been taken towards
achieving accreditation at some point in the future.
•
The management team, for a number of reasons, does not meet with any
regularity (it is reported that it has been “years” since the entire command staff
was together).
•
There are no annual reports, annual work plans or other documents that can be
used to proactively guide the Department.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 15
•
Visual observation of the City’s fire stations indicate that a number of deficiencies
exist and should be addressed. There is, at this time, no long term plan for
facility replacement or renovation included in the City’s capital improvement plan.
•
Likewise, there is no formal plan for replacing fire apparatus (vehicles) in a
routine scheduled manner.
•
The Department’s vehicle maintenance operations are challenged by its physical
space, single mechanic, lack of scheduled maintenance, etc.
•
Similarly, there are no plans in place for long term replacement cycles for SCBA,
turnout gear, etc.
•
The Training function does little to provide daily / weekly guidance to company
officers regarding on-shift training.
•
Record keeping in many areas of the Department are manual. This includes all
training files for Fire Department personnel.
•
Personnel providing training in the Department (including company officers) are
not required to meet NFPA training officer certification (Fire Officer 1 or 2 for
example). Nor are personnel providing training (including company officers)
required to provide lessons plans to the Training Chief for approval (to ensure
consistency, to allow lessons to be shared among staff, etc.). Nor are senior
personnel including the chief officers expected to provide training as part of their
responsibilities.
•
The Department does not routinely conduct training drills using multiple
companies (to simulate real fire-ground operating conditions). There are also no
expectations that training will be conducted at night, nor typically that training will
be conducted on weekends.
•
There are no periodic training needs assessments conducted. Training is
provided based on opportunities that arise – not based on an evaluation of where
training may be required. Neither are EMS certifications tracked by the
Department.
The points, above, represent significant management and organizational issues
for the Somerville Fire Department. The following sections in the report address these
issues.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 16
2.
KEY TO EVALUATING ANY ORGANIZATIONAL STRUCTURE IS THE NEED
TO IDENTIFY CRITERIA FOR ASSESSMENT.
In order to evaluate the organizational structure of the Somerville Fire
Department, the project team first had to identify the criteria by which the organizational
structure would be judged. The paragraphs, that follow, describe those criteria as well
as describe what is meant by each of them:
•
Accountability and Responsibility is clearly identified: The organization
must be consistent with the concept that clear lines of authority and decision
making are essential for any organization to achieve excellence. Areas of
responsibility are clearly delineated and points of accountability are readily
identifiable.
•
Span of Control or Communication is Optimal: Effective organizations are
structured so that lines of communication are identifiable and where there are
multiple reporting relationships, responsibility for communication and control are
clearly identified and understood.
•
There are essential checks and balances in place where necessary: As it
relates to this project, checks and balances are necessary in the area of clinical
performance review as opposed to operational performance review. For
example, effective EMS organizations are able to maintain a constructive and
remedial focus on clinical issues while maintaining formal organizational
discipline in the operational arena.
•
Structure is based on task requirements and work flow as opposed to
specialized skills of individual members: There is a tendency in some
organizations to organize work patterns around the specific passions or skills of
individual members. This results in high friction levels of most work processes
and the relationships between group members and groups them.
•
Similar titled positions have similar responsibilities and levels of
accountability: The organization should be structured such that decision
making authority and the ability of decisions to impact the organization in a
strategic way are all found at similar levels of the hierarchy.
•
Support functions are logically grouped and do not, through this grouping,
create additional layers of oversight: Organizational structures should group
support functions together, separated from operations, only when the scale and
scope of the operation requires it.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 17
The section, that follows, provides our analysis of the current organizational
structure and opportunities for improvement.
3.
THE CURRENT ORGANIZATIONAL STRUCTURE LARGELY MEETS THE
CRITERIA FOR AN EFFECTIVE ORGANIZATION.
The current organization of the Fire Department is along fairly typical lines, as
shown, below:
The exhibit, that follows, provides a graphical assessment of the current
organizational structure. Note the “!” marks in a box indicate that the organizational
unit meets that criteria described in the preceding section of the report.
Organizational
Unit
Authority
Span of
Control
Checks
and
Balances
Based on
Work Flow
Similar
Titles /
Similar
Duties
Support
Integrated
into Ops
Office of the Fire
Chief
!
!
!
!
!
Shift
Operations
!
!
!
!
!
Training
!
!
!
!
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 18
Organizational
Unit
Authority
Span of
Control
Checks
and
Balances
Based on
Work Flow
Similar
Titles /
Similar
Duties
Support
Integrated
into Ops
Special
Operations
!
!
!
!
!
Fire Alarm
!
!
!
!
!
!
Fire Prevention
!
!
!
!
!
The paragraphs that follow provide a summary of the project team’s findings and
conclusions regarding the current organizational structure of the Fire Department:
•
The overall organizational structure of the Fire Department effectively represents
the primary mission and the administrative necessities of the Department.
•
There are no operational functions assigned within the Office of the Chief – an
appropriate organizational approach in an agency of this size.
•
Functions are logically grouped in the Department.
•
The use of Chief level officers to oversee small functions (such as training and
prevention) with little or no subordinate staff is unusual in agencies of this size.
•
Similarly, the number of chiefs on shift should be evaluated (there are currently
two – for eight or nine fire companies).
The following section considers the organizational options available to the Fire
Department.
4.
SEVERAL ORGANIZATIONAL ALTERNATIVES WERE ASSESSED IN AN
EFFORT TO IDENTIFY AN ASSISTANT CHIEF POSITION.
In order to evaluate the true effectiveness and efficiency of the current
organizational structure, it is important to consider other alternatives and to compare the
relative merits or issues with each relative to the current approach. Our review
identified the most serious issues to be the lack of a second senior command staff
member outside the bargaining unit – at this time, only the Fire Chief is a non-
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 19
bargaining unit member. This presents several challenges to the City and the
Department:
•
The Chief does not have a command officer with whom to confer on employee or
other significant management issues that might impact bargaining unit
employees.
•
There is no other person, beyond the Chief, who can participate in the
disciplinary process who is not part of the same bargaining unit.
•
When the Chief is away from the Department, there is no other employee who
can be left in charge that is not a member of the bargaining unit – raising
concerns regarding discipline and management.
The dot points, which follow, provide a brief description of the alternatives
considered by the project team:
•
Option 1 – Eliminate the Deputy Chief in the Operations Chief role and convert
that position to Assistant Chief. Replace them with Captains reporting to one
Deputy Chief for Support Services. Create a Training Captain position to
coordinate training functions.
•
Option 2 – Eliminate the Deputy Chief classification entirely. Create two
Assistant Chiefs, who are not part of the union, with Captains handling staff
assignments and District Chiefs providing shift management (1 per shift). Create
a Training Captain position to coordinate training functions.
•
Option 3 – Maintain the Deputy Chief positions on the shifts. Add the position of
Assistant Chief, not in the Union, supervising all five Deputy Chiefs and reporting
to the Chief.
Organization charts for these options are presented in the following exhibits:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 20
Option 1: Eliminate One Deputy Chief Position
Create a Training Captain
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 21
Option 2: Eliminate All Deputy Chief Positions
Create Assistant Chiefs and a Training Captain Position
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 22
Option 3: Create an Assistant Chief Position / Eliminate One Deputy Chief Position
Each of these alternatives represents a significant departure from the current
approach to managing the Somerville Fire Department. Each would be accompanied
by changes in either the number of positions or the classifications in the Fire
Department. The City could, for example, increase the headcount in the Department by
one position and simply insert an Assistant Chief into the table of organization. The
alternatives, above, show that there are options which can partially offset the cost of this
improvement as well as resulting in enhanced management and control of the
Department.
The approach utilized for implementing this change will be key to its success –
particularly for any of the options that result in demotion of existing positions. The
project team recommends the following:
•
Conversion should wait until one of the existing Deputy Chiefs retires or resigns.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 23
•
When this takes place, the Assistant Chief position should be created and a
process utilized to fill it from existing Deputy Chiefs.
•
Once that has been completed, Deputy Chief or newly created Captain positions
should be filled and the reorganization completed.
Unless the City chooses to simply create a new Assistant Chief position (i.e.,
increase headcount) the project team recommends waiting until there has been some
form of attrition before making these changes.
5.
THERE
ARE
POSITIVE
IMPACTS
AND
CHALLENGES
TO
ANY
ORGANIZATIONAL ALTERNATIVE
The exhibit, below, provides a summary of the benefits and challenges posed by
the three options described graphically in the previous section.
Option
Benefits
Challenges
Option 1: Eliminate one Deputy
Chief position / consolidating
Support Services under 1
Deputy Chief.
• Fiscal savings associated
with elimination of the
position (reduced through the
creation of another position).
• Improved intra-departmental
focus on Support Services.
• Improved departmental
focus, through one
commander, on the range of
non-suppression services.
• Does not get an Assistant
Chief position out of the
bargaining unit.
• Elimination of a Deputy Chief
position.
• Creation of a Captain
position handling training
coordination.
• Pressure from union on
changing work conditions
due to position reduction.
Option 2: Eliminate all Deputy
Chiefs, create two Assistant
Chief positions.
• Significant cost savings
through the elimination of 7
Deputy Chief positions.
• Would create two positions
that are not in the union, in
addition to the Chief. This
would provide for additional
management capacity
outside the union.
• Elimination of all Deputy
Chief positions.
• Creation of a Captain
position handling training
coordination.
• Pressure from union on
changing work conditions
due to position reduction.
• Reduced supervision on the
shift. Reduced supervision
of major incidents through
the elimination of one shift
chief officer.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 24
Option
Benefits
Challenges
Option 3: Create one Assistant
Chief position, consolidating
Support Services under a single
Deputy Chief.
• Results in the creation of an
Assistant Chief position.
• The organizational structure
focus is improved somewhat
with a single Deputy Chief
responsible for support
services.
• No fiscal savings due to the
net creation of positions.
• Elimination of a Deputy Chief
position (current Operations
Chief).
• Pressure from union on
changing work conditions
due to position reduction.
The options, above, are certainly not the only options for changing the
organizational structure of the Fire Department. However, these options each are
intended to either address an issue identified by the project team, or are intended to
represent an option (creation of at least one Assistant Chief) that was identified within
the Department. The table, that follows, shows the cost implications of each of the
alternatives:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 25
Option
Position
Changes
Salary /
Position
Benefits /
Position
Total Impact
One
-1
Deputy Chief
$96,672
$48,336
-$145,008
1
Captain
$75,708
$37,854
$113,562
One - Total
-$31,446
Two
-7
Deputy Chief
$96,672
$48,336
-$1,015,056
2
Assistant Chief
$106,339
$53,170
$319,017
1
Captain
$75,708
$37,854
$113,562
Two - Total
-$582,477
Three
-1
Deputy Chief
$96,672
$48,336
-$145,008
1
Assistant Chief
$106,339
$53,170
$159,509
Three - Total
$14,501
The exhibit shows that there is a wide range of operating cost impacts from the
three alternatives – from moderate savings (Option 1) to significant savings (Option 2)
to significant increased annual cost (Option 3).
Recommendation: The City of Somerville should convert the Operations Deputy
Chief to an Assistant Chief position. This will cost an estimated $14,500 per year.
6.
MANAGEMENT SYSTEMS IN THE FIRE DEPARTMENT ARE VARIED WITH
MANY
NOT
BASED
ON
DATA
FOR
DECISION
MAKING
AND
ACCOUNTABILITY.
The Somerville Fire Department represents a multi-million dollar investment on
the part of the community. For the investment, the community expects to receive
effective and efficient fire, rescue and EMS services. In order to assure the community
that these funds are well-spent and that operations are being managed effectively, the
Fire Department must have data-driven management systems in place. In general,
management systems should be able to provide managers with insight into the following
critical areas:
•
Performance responding to emergencies.
•
Training for both fire and EMS skills.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 26
•
Use of leave (sick, vacation, etc.).
•
Budgetary performance.
•
Overtime utilization by cause.
•
Fire / EMS “run” reports and billing documentation.
The Matrix Consulting Group found that the Department’s key management
systems vary in their utility and in the level of utilization by the command staff. Our
findings are summarized, below:
•
Systems that provide for financial reporting are present and are under the control
of the City. Systems are in place which enable the Department to monitor
budgetary performance. These are linked to the City’s financial management
systems. The project team found that the Department reconciles its own
performance against the budget in an on-going manner, enabling potential
budgetary issues to be identified quickly.
•
Systems are also in place which enable detailed tracking of the use of overtime,
the use of leave, etc. – all key indicators on the utilization of personnel. The
project team found that the Department maintains detailed accounting of all
overtime utilized by reason. This enables overtime to be billed, for example, to
the ambulance account – rather than the general fund – when appropriate.
•
There are no performance measures established for the Fire Department (nor for
any other department in the City apparently). The result of this is that there is no
objective measure against which to evaluate the Department’s operations,
performance, etc. The lack of these targets can impact planning decisions
related to staffing, training, equipment purchases, etc.
•
The Department does not utilize available data to assess its own performance
internally. The project team found that key data elements were not being
captured by the dispatch process. These data would enable the Department to
assess its own “reaction” time to calls for service – this can not be reliably done
given the issues, found by the project team, with the data in the various reporting
systems in the Fire and Police Departments.
•
There are no internally developed performance objectives for response, on-
scene activities, etc. which are actively measured. Personnel are not held
directly accountable for their individual performance.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 27
The Fire Department command staff has focused on the oversight of key
financial indicators. This is not surprising given the high level of scrutiny under which
the Department has come, particularly on financial issues in the past. There has been
relatively little focus by the City on the establishment of performance objectives for any
of the City’s departments – the Fire Department included – that are not outcome related.
Few performance measures are focused on service delivery – and therefore few are
useful in terms of measuring performance contemporaneously. This focus has changed
in the City recently as SomerStat continues to improve its focus, as well as that within
the operating departments, on these issues.
Performance measures should be easily understood and easily calculated.
Suggested performance measures for the Fire Department should include the following:
•
911 call processing time (call answered to call dispatched): 1 minute or less 90%
of the time.
•
Emergency call reaction time (call dispatched to unit en-route): 1 minute or less
90% of the time.
•
First unit drive time to emergency calls (unit en-route to unit on-scene): 5 minutes
or less, 90% of the time (should include calls in the City of Somerville only).
•
Quality assurance score of 85% of better on 90% of emergency medical calls for
service.
Other communities will also identify on-scene performance indicators, or
measures which must be met in training. These may include:
•
On-scene to charged line at the front door of a structure fire: three minutes or
less 90% of the time.
•
Water from hydrant to supply engine: two minutes or less 90% of the time.
The point of the performance measures is to identify the community’s
expectations in a quantifiable way, and to use the measurement of the Department’s
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 28
performance against these objectives to identify areas which may need improvement or
additional resources.
Recommendation: The Fire Department, in conjunction with the City’s
administration and policy makers, should work to develop specific performance
indicators for the SFD. The Department’s financial management systems are
adequate for ensuring that budgetary and overtime issues can be identified
quickly. Once these are in place, simple management systems focused on
tracking these indicators should be developed by the Department.
7.
POLICIES AND PROCEDURES IN THE FIRE DEPARTMENT, THOUGH
RECENTLY UPDATED, ARE NOT COMPREHENSIVE AND LEAVE MANY
ISSUES UNADDRESSED.
The Fire Department operates under the direction provided by its Rules and
Regulations for the Governance of the Fire Department of the City of Somerville. This
document has been issued by the Fire Chief under the authority granted to him by the
MGL Chapter 48 / Section 42. This document, in conjunction with the contract between
the City of Somerville and the bargaining unit, represent the two locally derived
documents that provide structure to the administration and operation of the Fire
Department.
The current “Rules and Regulations” are limited in their scope and do not cover
the comprehensive requirements of a modern fire / rescue department. The “Articles”
included in the current document include the following:
•
Officers General
•
Deputy Chief
•
Lieutenant
•
Mechanic
•
Drivers
•
Dispatcher
•
General Rules
•
Fire Alarm
•
EMS Coordinator
•
Uniforms
•
Training
•
Call Firefighters
•
Radio Procedures •
Attack Procedures •
House Cleaning
•
Accountability and Discipline
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 29
There are no dates on the specific “Articles” contained in the document as to
when they were reviewed and / or updated. The clear tracking of review and revision is
instrumental to ensuring that all staff are able to identify the most up to date version of
each policy or procedure. In addition, the project team found that the document is
updated solely by the Chief with little direct input from the Deputy Chiefs or other staff in
the Department.
The project team also found the following:
•
The document does not cover a number of topics which are critical for the fire /
rescue service delivery environment.
•
The current “Rules and Regulations” is focused on a mixture of administrative
and operational items with significant gaps in the document regarding topics such
as emergency medical response, infection control, risk management, etc. A
detailed list, developed by the US Fire Administration, is provided later in this
section of the report.
•
The document has a number of intensely detailed passages followed by very
general guidelines.
•
The document, though organized in the table of contents, is difficult to follow
given the way is has been laid out and the way in which the page numbering can
change mid-page.
Policy creation is a rigorous and demanding process, especially if it is based
entirely on local development efforts. Fortunately, a number of fire departments
nationwide have developed policies that could form the basis for the comprehensive
development of policies for the SFD. In addition, the Commission on Fire Accreditation
International has developed materials that could support the Department’s policy
initiative. We are not suggesting that documents from other sources be copied into a
SFD format but that existing materials be used to help the Department structure its
efforts. The Matrix Consulting Group project team recommends that the Department
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 30
adopt the following process for completing this, as recommended by the US Fire
Administration:
•
Conduct a complete needs assessment of the policies and procedures of the Fire
Department. The current policies are so out date and incomplete, it would likely
be more practical to obtain an up-to-date policy from a neighboring community
(or a model policy from the Commonwealth, if it is available). This needs
assessment should take the following form:
-
Form a committee made up of Fire Officers and Firefighters to develop a
needs assessment. Coordinated committees might be established on
each shift.
-
Identify any unique or unusual characteristics of the community. What are
the major sources of risk? Are there unique demands for service placed
on the Department? Who does it interact with frequently (police, water,
other fire departments)? Are there response impediments that need to be
considered? Are there seasonal issues that need to be considered?
-
Consider the current policies as well as any potential models from which
the policies could be developed.
-
Do the policies that exist address the needs of the community and the
Department? Are there major gaps in them or are they too specific?
-
Develop a list of policies and procedures that should be in place. Do the
model policies address the issues relevant to the SFD? Are there major
gaps in the policies?
-
Do post-incident reviews suggest major gaps that need to be addressed?
Have there been changes in the law? Have any issues been identified
during training? Has equipment been changed? Are there new apparatus
that need to be considered?
-
Are there guidelines from professional and trade organizations that
suggest policy or procedure approaches?
•
Once the needs assessment has been done, the Fire Department can turn to the
process of developing new policies or modifying existing ones. This process can
be accomplished as follows:
-
Establish one or more teams for each section of the policy manual to
handle specific editing and writing tasks.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 31
-
Develop specific procedures for writing, sharing and editing proposed
policies.
-
Develop a specific format for all policies and procedures.
-
Gather information and potential alternatives for each policy. Do not
reinvent policies that already exist elsewhere.
-
Analyze the various alternatives and select the one which most closely
matches the SFD approach to conducting fire and EMS operations.
-
Write the draft of the policy.
-
Review and test (if applicable) the proposed policy or procedure.
-
Ratify and approve the final version. Seek legal sign-off from the City’s
attorney if this is recommended internally.
•
The next step is to implement the policies and procedures. This is also a
complicated process and involves the following:
-
Assessment of what is being implemented. Is this a total replacement or
an annual update?
-
Provide notice to, and discuss policy changes with, personnel.
-
Assess training needs and develop training materials to ensure that all
personnel are properly briefed and prepared to consistently implement the
policies.
-
Track who has received new policies and who has been trained. Many
agencies require employees to sign an acknowledgement receipt.
•
The Department should have a process by which performance can be monitored
to ensure that:
-
All policies are being followed.
-
All policies match the actual practices and that they meet the needs of the
agency and community.
-
All policies are reviewed annually to ensure that they continue to be
relevant. A process similar to the one described above should be used to
review polices.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 32
The preceding dot points describe a process by which policies can be developed,
reviewed and implemented. The following points provide a list of standard operating
guidelines the SFD should consider developing.
•
Management and Administration
-
General Administration
••
Organizations
••
Facilities
••
Emergency Vehicles and Special Apparatus
••
Equipment and Supplies
••
Finance
••
Training, Education and Exercises
••
Information Management
-
Member Health and Assistance Programs
••
Medical Screening / Health Assessment
••
Health and Wellness Promotion
••
Performance Evaluation Process
••
Post-Injury Rehabilitation
••
Employee Assistance
••
Facility Safety
••
Hazard Communication
-
Organizational Planning and Preparedness
••
Strategic / Master Plan
••
SOP Development
••
Risk Management
••
Emergency Operations Planning
••
Mutual / Automatic Aid
•
Prevention and Special Programs
-
Public Information and Education
••
Working with the Public
••
Working with the Media
••
Emergency Public Information
••
Public Education
••
Public Relations
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 33
-
Building Inspections and Code Enforcement
••
Authorities and Codes
••
Design and Plans Review
••
Residential Inspections
••
Commercial Inspections
••
Industrial Inspections
••
Code Enforcement
••
Record Keeping
-
Special Programs
••
Fire Cause and Arson Investigation
••
Hydrant Maintenance
••
Other Special Programs
•
General Emergency Operations
-
Operating Emergency Vehicles
••
Driving Emergency Vehicles
••
Riding Emergency Vehicles
••
Operating Special Apparatus
••
Vehicle Accident Reporting and Investigation
••
Use of Personal Vehicles
-
Safety at Emergency Incidents
••
Applicable Standards
••
Risk Management Guidelines
••
Safety Officer
••
Protective Clothing and Equipment
••
Personnel Accountability System
••
Responder Exposure Control
••
Hearing Conservation
••
Operating in a Hostile Environment
••
Operating on Roadways
••
Incident Scene Rehabilitation
••
Medical Support
••
Incident Termination
-
Communications
••
System Access
••
Definition of Alarms / Dispatch Protocols
••
General Procedures
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 34
••
Emergency Signals
••
Alternate Radio Frequencies
••
Mobile Data Terminals
••
Departmental Cell Phones and Pagers
••
Mutual Aid Companies
••
Situation / Status Reports
••
Use of Personal Cell Phones and Pagers
-
Command and Control
••
Incident Command / Incident Management System
••
Mutual / Automatic Aid
••
Incident Scene Management
••
Staging
••
Transferring Command
••
Public Information
••
Record Keeping
-
Special Operations
••
Aircraft Operations
••
Boat and Watercraft Operations
••
Special Unit Operations
••
Bomb / Hazardous Device Threats or Confirmed Incidents
••
Terrorism Incidents
••
Civil Disturbances
-
Post-Incident Operations
••
Post-Incident Analysis
••
Post-Incident Recovery
••
Incident Record Keeping and Reporting
••
Injury / Exposure Reporting and Investigations
••
Critical Incident Stress Debriefing / Defusing
•
Fire Suppression
-
Fire Suppression Risk Management
••
Required Use of Personal Protective Equipment
••
Rapid Intervention Team
••
Evacuation (Firefighters)
••
Air Monitoring
-
Company Operations
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 35
••
Incident Staffing
••
Water Supply
••
Tanker / Tender Operations
••
First-In Engine Operations
••
Second-In Engine Operations
••
Truck Company Operations
••
Rescue / Squad Company Operations
••
Special Units
-
Tactical / Strategic Guidelines
••
Incident Size-Up
••
Automatic Alarms
••
Offensive and Defensive Operations
••
Apparatus Placement
••
Forcible Entry / Gaining Access
••
Foam Operations
••
Ventilations
••
Hot / Cold Weather Conditions
••
Sprinkler / Standpipe Operations
••
Apartment / Condominium Operations
••
Commercial Building Operations
••
Salvage
••
Overhaul
••
Exposures
-
Special Facilities / Target Hazards
••
High-Rise Operations
••
Clandestine Drug Labs
••
Correction Facility Operations
••
Industrial Facilities
••
Other Special Structures
-
Special Fire Suppression Operations
••
Aircraft Firefighting Operations
••
Special Unit Operations
••
Wildfire Operations
•
Emergency Medical Response
-
Emergency Medical Response Risk Management
••
Incident Infection Control
••
Protective Clothing and Equipment
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 36
••
Lifting / Moving Patients
••
Hostile Situations
-
Pre-Hospital EMS First Response
••
Delivery Model
••
Patient Care
••
Treatment Protocols
••
Medical Devices and Equipment
••
Biohazard and General Waste Disposal
••
Clothing / Equipment Decontamination
-
Patient Disposition and Transportation
••
Destination Guidelines
••
Method / Mode of Transport
••
Ambulance Operations
••
Helicopter Operations
-
Management of EMS Operations
••
Re-Supply / Procurement of Supplies
••
System Inventory
••
Designation of Treatment Facilities
••
Data Collection and Reporting
••
Quality Improvement System
••
Research and Reporting
••
Standard of Care
••
Patient Care Reporting
••
Patient Documentation and Billing
-
Special EMS Operations
••
Mass Gatherings
••
Hazardous Materials Team Medical Monitoring
••
EMS Operations at Hazmat Incidents
••
EMS Operations at Technical Rescue Incidents
••
EMS Operations During Disasters
••
EMS Operations in the Rehabilitation Area / Sector
•
Hazardous Materials Response
-
Hazardous Materials Response Risk Management
••
Personal Protective Equipment
••
Hazardous Materials Personal Safety
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 37
••
Air Monitoring
-
First Responder Operations
••
Roles and Actions
••
General Response Procedures / Emergency Response Plan
••
Recognition and Identification
••
Notification
••
Site Management and Scene Setup
••
Emergency Decontamination
••
Defensive Actions
-
Special Hazmat Operations
••
Operating with Hazmat Teams
••
Public Protection Options
••
Environmental Restoration
•
Technical Rescue
-
Technical Rescue Risk Management
••
Personal Protective Equipment
••
Lock Out / Tag Out
••
Air Monitoring
-
Rescue Operations
••
Scene Stabilization
••
Rescue Equipment
••
General Rescue Operations
••
Rescue Teams
-
Special Rescue Operations
••
Ice Rescue
••
Water Rescue
••
Confined Space Rescue
••
Structural Collapse Rescue
••
Rope Rescue
••
Trench and Excavation Collapse
••
Aircraft Extrication
•
Disaster Operations
-
Organizing for Disaster Situations
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 38
••
Disaster Management
••
EOC Organization
••
ICS / EOC Interface (NIMS)
••
Activation Levels
••
Personnel Assignments and Responsibilities
••
Personnel Notification Procedures / Call-In Procedures
••
Disaster Training
••
Disaster Preparation
-
Disaster Operations Risk Management
••
Personal Protective Equipment
••
Disaster Operations Personal Safety
••
Protection of Facilities and Equipment
••
Accountability of Personnel
••
Suspending Operations
••
Member Injuries and Fatalities
-
Disaster Operations
••
Disaster Operations Center
••
Adjusted Levels of Response
••
Disaster Communications
••
Response Unit Routing and Placement
••
Damage Assessment
••
Specialized Equipment
••
Building Safety Evaluations
••
Community Emergency Response Teams
••
Mitigation Activities
••
Curtailing Disaster Operations
Successful and safe operations, as well as broader risk management strategies,
are grounded in an agency’s policies and procedures. The current “Rules and
Regulations” does not provide a comprehensive basis from which the SFD can be
effectively and efficiently operated.
Recommendation: The Fire Department should develop a new, comprehensive,
policy and procedures manual. The Department should first take steps to identify
model examples from Massachusetts to simplify their development. Second, a
committee of staff from all ranks should be formed to ensure that the adaptation
of policies and procedures to the Fire Department is done with appropriate focus
on the needs of the community and the SFD.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 39
8.
ASSESSMENT OF THE TRAINING PROVIDED TO PERSONNEL SHOWS
THAT A NUMBER OF IMPROVEMENT OPPORTUNITIES ARE AVAILABLE.
A review of the training program shows that there are several major issues
regarding the way in which training is provided by the Fire Department:
•
The unpredictability and turnover in the Training Chief position is viewed as a
major concern by line staff and managers.
•
There are no performance measures or standards for performance for training or
for basic skills.
•
There are no “minimum standards” set for new employees to meet and to be
continually maintained by current employees.
•
The company officers do not receive coordinated support for in-station training.
•
There are few opportunities for multiple companies to train together in either
scenario based exercises or on technical issues.
•
There is little or no formal training provided for supervisors, managers or
executive staff.
The current program is dependent on the creativity, motivation and preparation of
the company officers who work on the daily training. The project team recommends
that the Fire Department take a number of steps to address these issues. These steps
should include the following:
•
Maintain a Deputy Chief in Training. This is discussed in the organizational and
management chapter. Consider a 3-year appointment to this position to maintain
continuity in this critical function.
•
The Fire Department should adopt a series of minimum standards for new and
incumbent employees. These minimum standards should be made part of the
process by which new employees either pass or fail their probationary period.
These standards should continue to serve as the nucleus for in-station and multi-
company training. Recommended standards include the following:
-
Area familiarization.
-
Vehicle familiarization.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 40
-
Use of SCBA system.
-
Incident command and safety.
-
Use of ropes.
-
Use of ladders.
-
Use of hoses and streams.
-
Medical equipment.
-
Use of other tools and equipment.
-
Ventilation.
-
Emergency vehicle driver training.
These standards require the company officer assigned to the new employee to
mentor the person to ensure their understanding of the minimum requirements.
In addition, each minimum standard has a test which is administered to ensure
their knowledge. This provides a formal methodology for assessing employee
performance and enables the Fire Department and the City to make more
informed decisions.
•
Develop a calendar-based system to support the company officers in their
delivery of the training program. This would consist of the development of a
series of key topics with supporting materials, pictures, reference guides, tests,
suggested activities that would be provided to each fire station or on the internet
for the Department when the citywide WAN is in place. The key elements of the
program are described, below:
-
The program would work by assigning a topic to a number (1-30).
-
A notebook (hardcopy or virtual) would be provided to each station.
-
Each topic would be covered when the date corresponds to its topic
number.
-
This would ensure consistency (each topic would be taught from the same
set of materials – the “Somerville way”).
-
The list of topics can be as narrow or broad as the Department desires. It
can remain the same or can be changed quarterly or annually. Example
topics include the following:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 41
••
Ventilation
••
Overhaul
••
SCBA
••
Construction
••
Salvage
••
Entry
••
Hoses
••
Ground Ladders
••
Pumping
••
Fire Streams
••
Incident Command ••
Safety
••
Communications
••
Sprinklers
••
Streets
••
EMS
••
Hydrants
••
Policies
•
The training program should be developed in accordance with NFPA 1410 –
“Standard for Training for Initial Emergency Scene Operations.” This is a
standard which focuses less on topical skills training (as above) but also provides
for scenario based minimum standards for a fire agency. This approach can
easily be adopted to encompass both training as well as performance
assessment for the line crews. A number of specific minimum skills are defined
in the document. One example of the types of minimum standards set forth in
NFPA 1410 follows:
-
Forward-lay a hose 300 feet from a hydrant using a single supply line.
-
Advance a pair of attack lines 150 feet each from the engine.
-
Charge the lines so that the primary attack line can pump and maintain
100 gpm. The secondary (backup) line should be able to pump and
maintain a flow of 200 gpm.
-
This task should be completed by a 3-person engine company in less than
three (3) minutes.
•
Crews should be tested annually (or more often) on their ability to meet these
minimum qualifications. Those units that cannot meet these standards should be
immediately scheduled for training supervised by the Training Chief.
•
The Training Chief should also utilize the recommended standards from NFPA
1410 to develop and oversee multi-company training. This training should be
done on at least a quarterly basis for all units. The Deputy Chief on-duty should
be involved in the exercises and full incident command practices should be
utilized in all exercises involving any fire or rescue and all events with three or
more units on-scene.
•
All personnel from the rank of Lieutenant and above should be provided with
specific training to enable them to better oversee operations. The project team
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 42
recommends that the Fire Department adopt an approach recommended NFPA
1021 “Standard for Fire Officer Professional Qualifications.” This standard sets
forth requirements to achieve various classifications of Fire Officer 1 through Fire
Officer 4. These are summarized, in the exhibit which follows:
Fire Officer I
Fire Officer II
• Firefighter II
• Minimum standard for department.
• Familiar with budget process.
• Departmental operating procedures.
• Fire prevention and education.
• Cultural diversity.
• Methods of supervision.
• Group dynamics.
• Rights of management and bargaining unit.
• Contractual language.
• Ethics.
• Fire related ordinances.
• Basic writing and organizational skills.
• All from FO1
• Ability to evaluate member performance.
• Human resource policies of the city.
• Communicate orally an in writing.
• Preparing a project or divisional budget.
• Purchasing laws and regulations.
• Working with the press.
• Incident command, health and safety.
Fire Officer III
Fire Officer IV
• All from FO 1 and FO 2.
• Ability to research and analyze data.
• Working with the public outside the agency.
• Develop and oversee large budgets.
• Ability to evaluate construction for issues.
• All from FO 1, FO 2 and FO 3.
• Advanced training in personnel, administration,
legal and other issues.
• Advanced training in analysis and information
management.
• Training in long range planning and evaluation.
• Major incident oversight.
• Major incident planning.
This exhibit does not exhaustively cover the text of the 25-page standard.
However, it does show the sense of progression that is encouraged by this
program. The Fire Department could either adopt the standard formally (by
linking, for example, promotions to these various levels) or could design a
program for new and existing officers. Many of the elements of these programs
can be provided by the City’s Human Resources, Finance, Information
Technology, Purchasing and other support departments. The City should budget
an additional $50,000 in training funds to provide for outside training to
management personnel.
The training program of the Fire Department should be enhanced to improve the
consistency of training and to enhance the support of company officers. In addition,
particular focus should be given to enhancing the training given to new employees and
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 43
to management personnel. Specific steps that should be taken to enhance the delivery
of management training include the following:
•
Provide “grade appropriate” training to personnel in the Fire Department. Identify
the training needs that are relevant to officers and provide this to them. Do not
require officers who do not actively participate in line activities to spend time on
line training.
•
Access the programs made available at Bunker Hill Community College (BHCC)
that focus on training mid-managers and senior managers to be more effective
trainers. These classes focus on methods of instruction and identify the various
ways in which people learn and retain information.
•
Consider joint training exercises for managers in the Fire, Police and other City
departments. The focus should be on sharing training opportunities which have
broad applicability. City departments should focus on cross-cutting training
issues such as personnel, budget management, capital planning, etc. and
provide these to personnel in all public safety agencies in the City.
Recommendation: The Fire Department needs to make several major changes in
its training program. These include improving the continuity in the position of
Training Deputy Chief, development of a standards-based training program,
annual testing against these minimum standards, development of new hire
training, and provision of management training. The City should budget an
additional $50,000 to cover the cost of the management and supervisory training
- much of which can be provided in-house for no additional cost.
9.
THE FIRE DEPARTMENT HAS NOT ADOPTED THE INFORMATION
TECHNOLOGY SOLUTIONS COMMONLY FOUND IN HIGH-PERFORMANCE
FIRE/RESCUE AGENCIES. THE FIRE DEPARTMENT SHOULD BE
AUTHORIZED TO CREATE A MANAGEMENT ANALYST POSITION TO
SUPPORT MANAGEMENT AND ANALYSIS SIMILAR TO THE CRIME
ANALYST POSITIONS FOUND IN POLICE DEPARTMENTS.
This section addresses the key management and information systems that
should be in place within a modern fire-rescue agency such as the Somerville Fire
Department. The project team examined key management systems relating in the
Department. These systems are critical to ensuring that the Department operates both
effectively and efficiently. The key elements of a successful management system for a
Fire agency include the following:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 44
•
Formal Interaction – Does the management team interact in formal meetings
(set times, regular schedule, with agendas, etc.)? Are different groups of
managers brought together to focus on key issues, to communicate general
issues, to work on budget information, etc.?
•
Utilization of Data in Decision Making – Does the Department make use of the
data collected from calls, quality assurance reviews, inspections, etc. to make
informed decisions? Are analytical methods regularly employed to make
decisions regarding deployment, budgetary expenditures, etc.? Is there a culture
of making decisions using analysis rather than anecdotal information? Are there
sufficient staff resources to support analytical decision-making?
•
Accountability Mechanisms – Is there a mechanism in place by which staff can
be held accountable for assignments made? Do these systems provide for
accountability the same way throughout the organization?
•
Formal Policies, Procedures and Protocols – Are key policies, procedures
and protocols formally documented? Are they regularly reviewed and updated?
Does the review of these key documents involve a broadly based group? Are
policies and procedures widely available to all staff? Are staff held accountable
for compliance? Is there a formal “professional standards” function within the
Department?
•
Management Training – Does the City and the Department provide formal
training to officers as they are promoted and as part of their continuing
education? Do officers receive advanced tactical training, risk management
training, personnel policy updates, etc.?
•
Utilization of Technology – Does the Fire Department make maximum use of
technology to enhance effectiveness and efficiency? Are current investments
being used effectively? Has the Department planned to adopt technology in the
future that will enhance services or management of services?
The project team has the following observations and findings regarding the
management of the Fire-Rescue Department:
•
The SFD also makes use of ad hoc groups to address special projects.
•
The project team found that the use of data by the Fire Department occurs
sporadically if at all. Examples include the following:
-
Operations data is not tracked by unit, station, battalion, etc. to monitor
performance of individual units or officers.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 45
-
Response time data are not regularly analyzed or evaluated at any level of
the organization.
-
Training data cannot, at present, be tracked by individual.
-
District Chiefs and others are rarely expected to utilize formal methods for
evaluating issues assigned outside of operations – for example, the
decision to adopt a new piece of equipment or a new tactic is only
undertaken following a formal research process.
-
There are no analysts to support the operations of the Fire Department.
This means that senior staff are left to perform their own research, rely on
less senior sworn staff to perform various analytical tasks, etc.
-
Extensive data are collected in various operational areas through the CAD
/ RMS system, training records, etc. However, many of these data cannot
be easily accessed under current information systems.
-
There is not a particular culture of “analysis” within the Fire Department.
The awareness that data can provide powerful – critical – information for
fire-rescue managers is growing nationally. Senior staff will need to be
able to make a case for additional resources predicated on proof derived
from analysis – rather than on anecdotal approaches that have historically
been acceptable. This change will need to be developed and fostered by
the command staff.
•
The Fire Department does not have a systematic method for ensuring
accountability for staff assignments or other routine tasks. The current
approaches rely upon the institutional memory of the command staff as a group
to ensure compliance by individuals. Given the complexity of the SFD, this
approach can no longer be viewed as appropriate. The City should obtain a
software driven solution that allows assignments to be made and tracked and to
allow progress on assignments to be followed. It is equally important that such a
solution does not add excessively to the workload of the command staff.
•
The Fire Department does not currently maintain a “command college” for its
Chiefs. Additional support for new chief-level officers would be appropriate –
particularly focused on personnel, risk management and other key management
skills not typically covered as part of company officer training.
•
The Fire Department should begin to engage in a number of projects focused on
enhancing the utilization of technology in the field and in the administration of the
Department. The project team found the following examples:
-
There are no computers in the fire response vehicles – an increasingly
common tool found in progressive fire / rescue agencies.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 46
-
Personnel are not able to access critical records on-line from their
vehicles, leaving personnel using hard-copy books for limited pre-incident
plans.
-
There are no GPS or mapping solutions being utilized by the Fire
Department. This represents a lost opportunity in terms of improving
response time management.
The project team recommends that the Fire Department undertake the following
actions to make improvements in management and oversight:
•
The Fire Department should develop an accountability system to ensure that all
assignments are followed-up appropriately. A simple in-house system can be
developed using common office programs until a more sophisticated system can
be obtained. An electronic system is useful since issues can be sorted by due
date, individual, status, etc. The tracking system should have (at minimum):
-
Assignment
-
Data assigned
-
Due date
-
Responsible Individual
•
Key measures should be identified by the senior staff and tracked regularly.
Examples might include:
-
Reflex time (overall, by station, by unit, by major call type)
-
Dispatch processing time
-
Drive time
-
Call concurrency
-
Response times by time of day, etc.
-
Number of inspections per inspector
•
Begin a process of information systems enhancement in the Department –
including consideration of contracting for a full needs assessment.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 47
•
Create a new analyst position, assigned to the Office of the Chief. This position,
similar in training and background to crime analysts typically found in police
agencies, should be a civilian who is trained as an analyst – familiar with
spreadsheets, statistics, use of analytical tools including GIS. The time of this
new position should be dedicated to both routine tasks (providing management
reports focused on response performance, leave utilization, etc.) and to provide
support to special projects undertaken by the command staff of the Department.
This will be critical in supporting the Department if it is to move towards a culture
which utilizes data for decision making.
Recommendation: The Fire Department should undertake several steps to
enhance the utilization of information and analysis in support of decision making.
Included in these steps should be the creation of a new Fire Analyst position for a
total cost of $80,000 annually. The Department should also take steps to improve
staff accountability, improve new-chief officer management training and the
adoption of key performance measures to be regularly tracked.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 48
3. ASSESSMENT OF FIRE ALARM
This chapter focuses on staffing and performance measurement within the Fire
Alarm Office of the Fire Department. The City of Somerville operates a separate Fire
Alarm Office (call taking and dispatching for the Fire Department) from the 911 PSAP /
dispatch center managed by the Police Department.
1.
METHODS FOR ANALYZING STAFFING
The Matrix Consulting Group takes the general approach that staffing, wherever
possible, should be related to two key factors: the workload to be handled by the staff
in question and the public policy decisions made with regard to service levels for each
facet of the operations. Assessing the number of personnel required to provide call-
taking and dispatching services in a large center such as Fire Alarm requires analysis of
several factors as well as several public policy decisions.
(1)
How Long a Dispatcher Should Be Occupied with Workload Is a Function
of Several Factors.
The calculation for net availability noted in the previous chapter essentially
results in the amount of time each Dispatcher is available to perform work. In any
profession, however, no position is occupied 100% of the time. By example, many labor
intensive professions, such as fleet mechanics, are ideally occupied 80% of the time
performing direct work on vehicles. This helps ensure productivity and, in the private
sector, profitability. More relevant to the public safety field, urban and suburban law
enforcement agencies would typically strive for patrol staff to have from 45%-50% un-
committed patrol time thereby allowing them to selectively work, in this “free time,”
particular community-oriented problems. This proportion of un-obligated time also
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 49
allows for patrol units to generally be available for relatively rapid response to
community generated calls for service.
How much time is dedicated to actual work in the public safety dispatch field is a
function of several inter-related variables. An allowance needs to be made regarding
the proportion of time desirable to have a dispatcher actually involved in call handling,
radio transmissions, keyboard entry, records research, etc. There are several reasons
why direct task allocation should not be nearly 100%, including the following:
•
Dispatch centers which have excessively high utilization levels tend to "burn-out"
staff and consequently have high levels of employee turnover.
•
Professions that require extreme concentration during work activities, such as
dispatch, air traffic control, or other professions in which failure brings
unacceptable risk, should have lower work utilization rates.
•
Dispatch centers which have high utilization levels experience "queuing"
problems in which responses to incoming telephone calls and radio
transmissions are delayed because the dispatcher is pre-occupied with other
concurrent workload.
•
In dispatch centers with high utilization quality begins to suffer because
dispatchers must cut calls and radio exchanges short, thereby impacting
dispatcher effectiveness, perceived customer service, and potentially safety in
the field for law enforcement, fire, and emergency medical response
professionals.
Based on these variables the project team typically uses a utilization rate of 25-
30% for dispatchers. This implies that dispatchers will be busy performing work an
average of 20 minutes per hour or one second every two seconds of net available time.
It should be noted that this utilization or “occupancy rate” is one of the primary drivers in
staffing requirements, particularly for larger dispatch centers. Modifying this variable by
relatively small increments can have an important impact on staffing requirements. This
will be noted throughout this chapter.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 50
2.
ANALYSIS OF STAFFING USING CURRENT DEPLOYMENT
The first approach that the project team utilizes is to assess the staffing required
to meet the current deployment in Fire Alarm. In effect, we are asking the question:
what level of staffing is required to efficiently staff operations in the Department? The
questions that need to be addressed are the following:
•
What is the availability of Dispatchers to meet staffing needs?
•
What level of staffing is Fire Alarm deploying to meet expectations for service
delivery?
The following exhibit shows the current level of net availability in Fire Alarm. Net
availability is, simply explained, the total time left over after all leaves and other
absences are subtracted from the hours that each Dispatcher is scheduled to work in a
given year:
Based on 2007 - 2009 Personnel Data / Estimates
Position
Dispatchers
Notes / Description
A
16,430.00 Total hours for all full time employees
B
1,568.00 Total vacation and holiday leave (total hours)
C
1,021.00 Total sick leave (total hours)
D
216.00 Total personal leave (total hours)
E
- Total training leave (total hours)
F
- Total military, FMLA leave, etc. (total hours)
G
- Total lunch and break (total hours)
H
100.00 Total other (meetings, light duty, special assignments, etc.)
I
2,905.00 Total unavailable time = Total B through H
J
13,525.00 Net Available Work Hours (NAWH) = A – I
K
1,352.50 Net Available Work Hours per employee (NAWH from J above)
L
65.02%
Net Available Divided by Total Hours Scheduled / Employee
This table shows that the Fire Alarm Operators, based on average usage in the
calendar years 2007 through 2009, were available an estimated average of 1,352 hours
out of the 1,643 hours they were scheduled to work on average (this does not include
overtime). This is equivalent to a net availability of 65% - or conversely, that personnel
are not available to work 35% of the time. This is a critical figure that goes directly to
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 51
the number of total fulltime equivalents required to staff a given 24-hour position in Fire
Alarm for the Fire Department, as shown, below:
Factor
Impact
Hours / Year for One Post
8,760.00
Net Availability
1,352.50
Positions Required to Cover
6.48
The next consideration is the level of deployment targeted in Fire Alarm itself. In
this analysis the project team has not challenged this level of staffing – this only
indicates how many personnel would be required to staff the various positions targeting
minimal levels of overtime utilization:
Element
Factor
Targeted Staffing (Line)
2.00
Staffing Required / Shift
6.5
Total Staffing Required
13.00
Current Line Staffing
10.00
Variance
(3.00)
This analysis shows several key points, each of which are summarized, below:
•
The staffing levels in Fire Alarm remain consistent with a target of two
Dispatchers on duty on the floor during all shifts. The current program requires
the use of some overtime.
•
Using the factors described, above, indicates that the Fire Department is staffed
appropriately – given current targeted deployment.
•
The current shift schedule is very inefficient. The levels of available time in Fire
Alarm, coupled with the very low levels of scheduled work hours, make this one
of the least efficient 24-hour operations in the project team’s experience.
Recommendation: Under current conditions and given public policy decisions,
the Fire Alarm unit is appropriately staffed to maintain two personnel on duty at
all times with minimal overtime.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 52
3.
SEVERAL MODELS EXIST FOR ASSESSING STAFFING REQUIREMENTS IN
FIRE ALARM. STAFFING IN FIRE ALARM SIGNIFICANTLY EXCEEDS
CURRENT
WORKLOAD,
PRESENTING
AN
OPPORTUNITY
FOR
INCREASED EFFICIENCY AND COST SAVINGS.
The Matrix Consulting Group continually researches various methods for
determining staffing requirements for functions such as emergency communications.
There are several models currently worth consideration.
(1)
APCO Project RETAINS Combines Workload and “Post” Positions in
Determining Total Staffing Required.
In the last few years APCO has published a staffing model as part of their Project
RETAINS efforts, developed by the University of Denver Research Institute. In effect,
the APCO Project RETAINS model requires several discrete data elements based on
actual workloads to be effective. These include:
•
Net annual staffing availability as discussed earlier in this chapter.
•
Average telephone busy time (call duration in seconds), from phone records.
This should ideally distinguish between, where appropriate, law and fire E-9-1-1
calls and administrative calls for service.
•
Average call completion time (in minutes, this includes time for keyboard data
entry, radio transmission, address verification, etc.). Average call completion
time is often not accurately available. While some agencies are capable of
collecting accurate radio transmission time, other dispatcher-related workload,
such as records checks or keyboard data entry by staff, is most often not
available.
•
Average Processing Time, or APT— which is the sum of the two above bullets.
What the APCO model fails to account for is the workload directly related to
other activities unrelated to telephone call’s workload; that is, by example, officer
initiated activities and the variety of tasks associated thereto.
•
Agent Occupancy Rate (AO) which reflects the proportion of time that the agency
desires a dispatcher to be occupied with workload. This is, in effect the opposite
of the prior model’s Utilization Rate which calculates the proportion of time a
dispatcher should be free of workload as opposed to busy with workload.
Nevertheless, the concept is the same although the mathematics differs.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 53
•
The model also provides for positions which are staffed based on workload and
positions staffed as “coverage” – i.e., positions that are staffed for public policy
reasons other than workload.
In brief, the APCO project RETAINS staffing model is a generally good
methodology with a few notable exceptions, but it is data intensive to the extent that
many agencies do not possess the level of detail required to properly complete the
model. The Matrix Consulting Group, using the APCO model as a baseline, has made
some slight revisions using major work activities captured as well as some assumptions
regarding other types of work.
(2)
Erlang C Models Were Developed for Telephone Queuing Applications and
Have Some Utility When Examining Dispatch Operations.
Another model that can be used to estimate staffing needs is based on the work
of Danish engineer Agner Erlang. Unlike the prior two models which estimates staffing
based upon community generated calls for service workload standards or actual work
outputs for major tasks, the Erlang model uses workload variables but the primary driver
is related to developing staffing levels based on desired performance or “response
time.” In effect, the Erlang Model is a predicted performance model that calculates the
probability of a certain average wait time that a caller would experience. One of the
primary criticisms of the Erlang model is that it assumes an acceptable “on-hold” time
for the caller. While initially this may seem to make the Erlang model impractical for use
in an E-9-1-1 PSAP environment, using national or local policy-driven standards for call
answering times eliminates the shortcoming of an assumed hold time. The Erlang
model uses calculations to find the amount of time it takes to answer a call based on a
certain level of staffing; these times can then be compared to standards to assure
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 54
performance minimums are achieved. Although the Erlang model has been traditionally
used to estimate staffing needs and performance predictions for non-emergency call
center operations, the input values can be manipulated such that the model is well
adaptable to a PSAP.
As it relates to standards, according to the National Emergency Number
Association (NENA), PSAPs should meet or exceed the minimum standard of 90% of
E9-1-1 calls answered within ten (10) seconds and 95% of E9-1-1 calls answered within
twenty (20) seconds. Local and state standards may be different but these standards
should be considered reasonable operating protocols. The Erlang model uses
sophisticated formulae based on probability theory, which will not be replicated in this
report. The Matrix Consulting Group uses the Erlang model to determine the number of
call takers required in a call taking center.
4.
ANALYSIS OF STAFFING USING WORKLOAD AS THE SOLE DETERMINING
FACTOR MAY NOT BE A REASONABLE APPROACH IN FIRE ALARM.
The second analysis conducted by the project team focuses on determining the
number of personnel required to handle call-taking and dispatching functions in Fire
Alarm – based entirely on workload. In other words, this model does not protect current
assumptions about staffing positions with essentially equivalent staffing for a major part
of each day. Nor does the model make any other assumptions about how personnel
would be specifically deployed across the day or into which functions – other than
broadly for call-taking and dispatching. The results of this model are provided, below:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 55
Element
Value
CALL TAKING
911 Call On-Phone Time
1.80
Other Calls On-Phone Time
1.10
911 Calls (2009 Estimated - Fire / EMS Related)
7,500.00
Non-911 Calls (2009 Estimated)
5,000.00
Sub-Total: 911 Call Processing Time (Minutes)
13,500.00
Sub-Total Non-911 Call Processing Time (Minutes)
5,483.33
Total Phone Time (Minutes)
18,983.33
Utilization (Erlang-C)
30%
Total Time for Call Takers (Minutes)
63,277.78
Total Time for Call Takers (Hours)
1,054.63
Net Availability
1,670.85
Call Taking Staff Required
0.63
DISPATCHING
Fire / EMS Radio Time (est.)
2.50
Fire / EMS Incidents (2008 projected)
7,500.00
Sub-Total: Fire / EMS Radio Time
18,750.00
Total Radio Time
18,750.00
Utilization Target
30%
Total Time Required for Radio (Minutes)
62,500.00
Total Time Required for Radio (Hours)
1,041.67
Net Availability
1,670.85
Dispatcher Staff Required
0.62
SUMMARY
Call Taking Staff Required
0.63
Dispatcher Staff Required
0.62
Total Staff Required (Volume)
1.25
Current Line Staffing
10.00
Variance
8.75
Note that this analysis shows that Fire Alarm is significantly overstaffed given the
workload handled by the unit – by almost nine of the ten positions assigned. This
model, based entirely on workload suggests that Fire Alarm would require a total 1.2
personnel – significantly less than the number that are currently authorized for Fire
Alarm operations. However, a closer examination also shows the following:
•
The total number of call taking and dispatching personnel required is equal – and
in both cases is less than a single total FTE of workload.
•
The total number of positions required is 1.2 FTE’s – significantly less than the
10 FTE’s currently authorized for Fire Alarm.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 56
The most significant impact of this would be that the model suggests that the Fire
Alarm Office could operate with many fewer positions than are currently authorized.
However, this would present major issues for the Office and the Fire Department.
These are summarized, below:
•
The analysis, based on workload, does not do an effective job of taking into
consideration the impact of concurrent events – particularly on the dispatching
side of the operation.
•
The analysis is also unable to properly account for the need to provide multiple
functions at the same time – dispatching and responding to fire units while
contacting power companies and other agencies.
•
This analysis makes a compelling case for consideration of some kind of merger
or consolidation of dispatch within the City or with neighboring communities – to
make the operations more efficient while at the same time maintaining the ability
to provide support for operations. The consideration of regionalization of
dispatch will be the focus of a study being overseen by the MAPC and the City.
Regardless of the outcome of this study, the City should consider consolidation
of Fire Alarm and police 911 / dispatch intra-City. This would almost certainly
enable the City to reduce staffing. As an example, the reduction of five positions
would result in savings of hundreds of thousands of dollars.
•
A shift to another schedule that focused on a full 40-hour work week for all
personnel would not allow the City to reduce staffing significantly if the intent
continues to maintain two personnel in a stand alone Fire Alarm operation. It
would be possible to reduce staffing to nine personnel if the entire unit moved to
a straight 4-on / 2-off schedule, as shown, below (this table shows on shift):
Day / Staff Person
1
2
3
4
5
6
7
8
9
10
A
1
1
1
1
0
0
1
1
1
1
B
0
0
1
1
1
1
0
0
1
1
C
1
1
0
0
1
1
1
1
0
0
Total Scheduled
2
2
2
2
2
2
2
2
2
2
•
Civilian staff cannot work more than 40 hours per week without being paid
overtime. This would make it complicated to assign them to a firefighter’s work
schedule that exceeds 40 hours / week
Recommendation: The City should maintain current staffing while Fire Alarm is a
stand alone entity. However, serious consideration should be given to merging
Fire Alarm with Police Dispatch or with neighboring communities. Savings from
doing so, assuming reduction of one fixed position, could exceed $500,000
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 57
annually. Shifting to a 4/2 scheduled (8-hour work day) would allow for the
reduction of one position, for savings of approximately $100,000.
4.
PERFORMANCE INDICATORS SHOULD BE MATCHED TO SERVICE
EXPECTATIONS AND OBJECTIVES.
It should be noted that dispatch centers like the Fire Alarm Office are not atypical
compared to many government entities in regard to its sophistication in measuring
performance, linking production to not only outputs but also to outcomes. Similar to
many jurisdictions, “performance reports” are generated, distributed, reviewed, and
filed, but little more is done with the contents. The City of Somerville has an increasing
focus on statistical management as overseen and typified by the SomerStat Office. The
most advanced performance measurement systems are generally found in the private
sector. Yet the value of performance measurement cannot be underestimated,
particularly since performance measurement is a core business practice and
fundamental to many successful companies. An oft-repeated phrase is, “You can
manage what you can measure.” The belief in this sentiment is the cornerstone of the
performance measurement philosophy.
We reviewed information made available from the Fire Alarm Office and framed
our review utilizing what is known as the “SMART” approach to performance
measurement and performance goals and objectives development. SMART is an
acronym for (S)pecific, (M)easureable, (A)chievable, (R)elevant, and (T)ime-bound.
Specifically:
Specific
Objectives must express the action and results required so that the reviewer
of the objective can see clearly whether or not the objective has been
achieved.
Measurable
When setting objectives, there must be some way of measuring and
validating whether the objective has or has not been achieved and to what
level of success or failure.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 58
Achievable
Although objectives should be challenging and encourage continuous
improvement, they must be reasonable and achievable.
Relevant
The objectives must be pertinent to the organization’s core business
practices and measure performance that reflects critical operations
fundamental to the success of the work unit’s mission.
Time bound
Objectives need to have clear time frames attached to them such that
success or failure can be analyzed within an established period.
While the Fire Alarm Office does not have a formal performance management
system or directives, typical elements tracked by dispatch operations include the
following examples:
•
Case Entry Protocol Compliance (95%)
•
Chief Complaint Selection Accuracy (95%)
•
Key Questions Compliance (90%)
•
Post-Dispatch Instructions Compliance (90%)
•
Pre-Arrival Instructions Compliance (95%)
•
Final Coding Accuracy (90%)
•
Total Compliance Score (90%)
•
“Customer Service” (95%)
Other examples that are tracked (but which are not driven by the Priority
Dispatch System) include the following:
•
911 – Average Ring Time (9 Seconds)
•
% 911 Answered in Less Than 20 Seconds (90%)
While these performance measures are excellent ones for managing the
operations of a dispatch center, some of them are not applicable to all functions in the
Fire Alarm Office. Many of the compliance measures are focused on emergency
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 59
medical call taking and dispatching and are driven by Priority Dispatch developed by the
National Academies of Emergency Dispatch.
The project team recommends that the City of Somerville adopt the following
performance / effectiveness measures for Fire Alarm:
Performance
Standard
Data Source
Audience
Frequency
911 Call Pick-Up
80% / 7 seconds
90%10 Seconds
98% 15 Seconds
Phone System
Management staff, all
oversight boards, staff,
public (website).
Daily monitoring with
monthly reporting.
Call creation in CAD
High: 85% / 90 secs
Medium: 85% in 180
secs
CAD
Management staff, all
oversight boards, staff,
public (website).
Daily monitoring with
monthly reporting.
Dispatch Serious Calls
85% events / 30 secs
95% events / 60 secs
CAD
Management staff, all
oversight boards, staff,
public (website).
Daily monitoring with
monthly reporting.
911 Callback
Failure < 0.10%
Quality Assurance
program / data
collection.
Management staff, all
oversight boards, staff,
public (website).
Daily monitoring with
monthly reporting.
Community Perception
(95% positive)
User Survey – every
200th call taken. Limit
questions to postcard
sized return mailer.
Management staff, all
oversight boards, staff,
public (website).
Monthly reporting.
Responder Perception
(95% positive)
Responder Survey –
every 200th call taken –
sent to primary unit.
Limit questions to
postcard sized return
mailer.
Management staff, all
oversight boards, staff,
public (website).
Monthly reporting.
Staff Retention (Annual
turnover rate of <15%).
Human Resources
Management staff, all
oversight boards, staff,
public (website).
Monthly reporting.
These performance measures can be adopted by the Fire Alarm Office almost
immediately (with the exception of the two surveys) with data currently captured in the
Fire Department.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 60
Recommendation: The City and the Fire Alarm Office should adopt a more
detailed and formal performance measurement and management plan. The
project team recommends the standards provided in preceding exhibit.
Additional standards may also be desirable, depending on policy objectives.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 61
4.
ASSESSMENT OF FIRE DEPARTMENT
SUPPRESSION OPERATIONS
The primary focus of the Fire Department is on the provision of EMS and Fire
response. This function involves the majority of the resources of the Department.
1.
ISSUES IDENTIFIED RELATING TO THE OPERATIONS OF THE FIRE
DEPARTMENT
The following exhibit compares the Somerville Fire Department to a series of
best practices:
Potential Improvements
Strengths
Potential Improvements
EMERGENCY RESPONSE GOALS
Response time targets are
directly related to designing a fire
protection system that can attack
structure fires prior to “flashover”
Flashover normally occurs
between 6 to 10 minutes after
ignition. Response time targets
can be modified based on built-in
protection
!
Stations are located to yield
response time targets of four
minutes for the first responding
unit for emergency fire and
medical calls with a fractile target
of 90%.
!
The Department has a 1-minute
“Reflex” time goal. Reflex time is
the time between the receipt of
the dispatch and the time that the
unit(s) is moving to respond or is
en-route.
!
The Department monitors reflex
times for each fire and EMS
company monthly.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 62
The Department is able to deliver
a minimum of 14 personnel (three
engines, a rescue and a truck)
with a travel time for all
responding units of 8-minutes on
a 90% fractile basis.
!
Cross-jurisdictional automatic and
mutual aid agreements are in
place to ensure that sufficient
resources are available to handle
major incidents.
!
Apparatus response areas are
clearly defined to ensure that the
closest unit will be dispatched to
each call.
!
!
Response protocols clearly define
the types and number of
responders dispatched to various
types of calls.
!
Response protocols (number of
apparatus and response speeds)
are designed to minimize
community risk by differentiating
between emergency and non-
emergency calls.
!
SUPPRESSION OPERATIONS
Command staff and company
officers are trained in an Incident
Command System (ICS), National
Incident Management System
(NIMS) or comparable approach.
!
The Department conducts
periodic training exercises that
include ICS incident simulation.
!
The Department has a 3-person
minimum staffing requirement for
both engine and aerial
operations.
!
Suppression crews are actively
involved in community smoke
detector and CO detector
awareness and inspection
programs.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 63
The Department has developed a
comprehensive risk assessment
and inventory information system
that quantifies fire risk or hazards
for planning purposes.
!
Fire company in-service
inspections are conducted to
identify life-safety problems and
fire hazards and to prepare pre-
plans.
!
Officers and Firefighters conduct
after action discussions and
produce after action reports on all
major emergencies
!
EMERGENCY MEDICAL SERVICES
The Department has a board
certified emergency medical
physician as its Medical Director.
!
The Medical Director prepares
and periodically updates written
medical protocols for the
Department.
!
The protocols are electronically
available to all members of the
Department
!
The Department provides in-
service EMS training programs
for its members as specified by
the Medical Director and by state
directives.
!
The Department has an
automated system to track the
training and certification records
of its EMS personnel.
!
The Department expedites the
delivery of cardiac response and
advanced EMS care by deploying
ALS personnel on engine
companies.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 64
The Department monitors and
analyzes response times for EMS
calls as follows:
(1) BLS (basic life support)
response within 4-minutes for
90% of calls; and
(2) ALS (advanced life support)
response within 8-minutes for
90% of calls (as measured by
travel time).
!
The Department has an
automated EMS incident
reporting system.
!
EMS providers have portable
computers that enable them to
complete reports on-scene and
automatically upload reports to
hospital and agency records
systems.
!
The Department has a quality
assurance and improvement
program to provide timely
feedback to employees and to
identify protocol and training
needs.
!
The Department’s Medical
Director is actively involved in the
agency’s quality assurance
program.
!
The Department has established
a goal of reviewing a percentage
of its run reports and discussing
the report with the responders.
!
Emergency Medical Dispatch
(EMD) procedures are used to
provide callers with pre-arrival
care instructions.
!
The Department supports citizen
“self-help” programs by locating
defibrillators in high-risk areas
and by providing AED and CPR
training.
!
HAZARDOUS MATERIALS
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 65
Hazardous materials plans are
required to be submitted by
businesses with defined
hazardous materials on their
premises.
!
Sites with hazardous materials
are required to place a placard on
the exterior of their business.
!
Types of materials utilized and
typical quantities on-site are
noted as part of the pre-incident
planning process and these data
are included in those plans.
!
Pre-designated hazardous
materials routes are established
for large quantity transport
through the City.
!
All response staff are trained to
the Hazardous Materials
Responder Level 1,
!
Hazardous materials planning
and response is regionalized.
!
2.
THE CITY OF SOMERVILLE HAS NOT YET ADOPTED SERVICE LEVEL
STANDARDS
The adoption of performance standards for fire and EMS response is a critical
first step in the evaluation of fire, rescue, and EMS service levels and staffing
alternatives. While there are national standards that can be used to evaluate fire and
EMS service delivery, each community must identify the key risks and necessary level
of protection it needs based on its own unique circumstances. Once these performance
standards are established a community can assess its performance and determine if
current resources support the desired level of service.
(1)
Efforts to “Standardize” Service Level Objectives Are Based on Fire
Growth Behavior and Research on Cardiac Arrest.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 66
Nationwide, a great deal of effort and research has been put into developing
performance objectives for the delivery of fire and EMS services. This effort is critical
for agencies making decisions about deployment and location of emergency resources.
The objectives promoted for fire/rescue and EMS have their basis in research that has
been conducted into two critical issues:
•
What is the critical point in a fire’s “life” for gaining control of the blaze while
minimizing the impact on the structure of origin and on those structures around
it?
•
What is the impact of the passage of time on survivability for victims of cardiac
arrest?
The chart, that follows, shows a typical “flashover” curve for interior structure
fires. The point in time represented by the occurrence of “flashover” is critical because
it defines when all of the contents of a room become involved in the fire. This is also the
point at which a fire typically shifts from “room and contents” to a “structure” fire –
involving a wider area of the building and posing a potential risk to the structures
surrounding the original location of the fire.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 67
Note that this chart depicts a fire from the moment of inception – not from the
moment that a fire is detected or reported. This demonstrates the criticality of early
detection and fast reporting as well as rapid dispatch of responding units. This also
shows the critical need for a rapid (and sufficiently staffed) initial response – by quickly
initiating the attack on a fire, “flashover” can be averted. The points, below, describe
the major changes that occur at a fire when “flashover” occurs:
•
It is the end of time for effective search and rescue in a room involved in the fire.
It means that likely death of any person trapped in the room – either civilian or
firefighter.
•
After this point in a fire is reached, potable extinguishers can no longer have a
successful impact on controlling the blaze. Only larger hand-lines will have
enough water supply to affect a fire after this point.
•
The fire has reached the end of the “growth” phase and has entered the fully
developed phase. During this phase, every combustible object is subject to the
full impact of the fire.
•
This also signals the changeover from “contents” to “structure” fire. This is also
the beginning of collapse danger for the structure. Structural collapse begins to
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 68
become a major risk at this point and reaches the highest point during the decay
stage of the fire (after the fire has been extinguished).
It should be noted that not every fire will reach flashover – and that not every fire
will “wait” for the 8-minute mark to reach flashover. A quickly responding fire crew can
do things to prevent or delay the occurrence of flashover. These options include:
•
Application of portable extinguisher or other “fast attack” methodology.
•
Venting the room to allow hot gases to escape before they can cause the ignition
of other materials in the room.
•
Not venting a room – under some circumstances this will actually stifle a fire and
prevent flashover from occurring.
Each of these techniques requires the rapid response of appropriately trained fire
suppression resources that can safely initiate these actions. In the absence of
automatic fire suppression systems, access to interior fires can again be limited by a
safety requirement related to staffing levels. OSHA and related industry standards
require the presence of at least 2-firefighters on the exterior of a building before entry
can be made to a structure in which the environment has been contaminated by a fire.
In the absence of a threat to life demanding immediate rescue, interior fire suppression
operations are limited to the extent a fire service delivery system can staff to assure a
minimum of 4-people actively involved in firefighting operations. The second issue to
consider is the delivery of emergency medical services. One of the primary factors in
the design of emergency medical systems is the ability to deliver basic CPR and
defibrillation to the victims of cardiac arrest. The chart, that follows, demonstrates the
survivability of cardiac patients as related to time from onset:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 69
This graph illustrates that the chances of survival of cardiac arrest diminish
approximately 10% for each minute that passes before the initiation of CPR and/or
defibrillation. These dynamics are the result of extensive studies of the survivability of
patients suffering from cardiac arrest. While the demand for services in EMS is wide
ranging, the survival rates for full-arrests are often utilized as benchmarks for response
time standards as they are more readily evaluated because of the ease in defining
patient outcomes (a patient either survives or does not). This research results in the
recommended objective of provision of basic life support within 4-minutes of notification
and the provision of advanced life support within 8 minutes of notification. The goal is to
provide BLS within 6 minutes of the onset of the incident (including detection, dispatch
and travel time) and ALS within 10 minutes. This is often used as the foundation for a
two-tier system where fire resources function as first responders with additional (ALS)
assistance provided by responding ambulance units and personnel.
Additional recent research is beginning to show the impact and efficacy of rapid
deployment of automatic defibrillators to cardiac arrests. This research – conducted in
King County (WA), Houston (TX) and as part of the OPALS study in Ontario, Canada –
% Survival
Rate
0
%
20
%
40
%
60
%
80
%
100
%
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
Response in
Minutes
Survival
Rate
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 70
shows that the AED can be the largest single contributor to the successful outcome of a
cardiac arrest – particularly when accompanied by early delivery of CPR. It is also
important to note that these medical research efforts have been focused on a small
fraction of the emergency responses handled by typical EMS systems – non-cardiac
events make up the large majority of EMS and total system responses and this research
does not attempt to address the need for such rapid (and expensive) intervention on
these events.
The results of these research efforts have been utilized by communities and first
responders, often on their own with no single reference, to develop local response time
and other performance objectives. However, there are now three major sources of
information to which responders and local policy makers can refer when determining the
most appropriate response objectives for their community:
•
The Insurance Services Office (ISO) provides basic information regarding
distances between fire stations. However, this “objective” does little to recognize
the unique nature of every community’s road network, population, calls for
service, call density, etc.
•
The National Fire Protection Association (NFPA) promulgated a documented
entitled: “NFPA 1710: Objective for the Organization and Deployment of Fire
Suppression
Operations,
Emergency
Medical
Operations,
and
Special
Operations to the Public by Career Fire Departments.” This document (NFPA
1710) was published in 2001 and generated a great deal of dialogue and debate
– which is still on-going.
•
The Commission on Fire Accreditation International (CFAI) in its “Objectives of
Coverage” manual places the responsibility for identifying “appropriate” response
objectives on the locality. These objectives should be developed following a
comprehensive exercise in which the risks and hazards in the community are
compared to the likelihood of their occurrence.
While each of these efforts provides a reference point for communities to follow,
only NFPA 1710 offers any specificity. It is important to note that the performance
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 71
objectives (in terms of response times) provided in the NFPA 1710 document are
derived from the basic research previously described. These include the following (all
are taken from section 4.1.2.1.1 of NFPA 1710):
•
One minute (60 seconds) for the processing of an incoming emergency phone
call, including the completion of the dispatching of fire response units.
•
“One minute (60 seconds) for turnout time.” This is also called reflex time,
reaction time, “out-the-chute” time, etc. This is the time that elapses between
dispatch and when the units are actively responding.
•
“Four minutes (240 seconds) or less for the arrival of the first arriving engine
company at a fire suppression incident and / or 8 minutes (480 seconds) or less
for the deployment of a full first-alarm assignment at a fire suppression incident.”
•
“Four minutes (240 seconds) or less for the arrival of a unit with first responder or
higher level capability at an emergency medical incident.”
•
“Eight minutes (480 seconds) or less for the arrival of an advanced life support
unit at an emergency medical incident, where this service is provided by the fire
department.”
•
In section 4.1.2.1.2, NFPA 1710 goes on to state: “The fire department shall
establish a performance objective of not less than 90 percent for the
achievement of each response time objective specified in 4.1.2.1.1”
It is important to note the “and / or” found in the initial response objective
statement. This indicates that a system would meet the intent of the standard if it can
reasonably plan to deliver either the single unit, 4-minute travel time standard, the first
alarm, 8-minute travel time standard, or both. It should also be noted that it is implied
that the total time allotted is additive with each successive event. For example, a
system which arrived on-scene in 6-minutes or less 90% of the time (from time of
dispatch) would be in compliance – even if the turnout time was longer than a minute
(though that should clearly be improved).
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 72
It is also critical to note that these time objectives apply to emergency calls for
service – there is nothing in NFPA 1710 (nor in any other objective) that suggests that
communities cannot establish a differential response to calls for service determined to
be non-emergency in nature. A second element of the NFPA 1710 performance
objectives addresses unit and total response staffing. These objectives are described in
NFPA 1710 as follows:
•
Engine and truck companies should be staffed with a minimum of four personnel
(sections 5.2.2.1.1 and 5.2.2.2).
•
Section A.3.3.8 defines a company as either a single unit or multiple units, which
operate together once they arrive on the fire ground.
•
A total initial response is defined (in section 5.2.3.2.2) as having a total of 15
people (if an aerial is utilized) for 90% of calls. This is broken down as follows:
One (1) incident commander.
One (1) on the primary supply line and hydrant.
Four (4) to handle the primary and backup attack lines.
Two (2) operating in support of the attack lines, performing forcible entry.
Two (2) assigned to victim search and rescue.
Two (2) assigned to ventilation.
One (1) assigned to operate the aerial device.
Two (2) to establish an initial rapid intervention team.
•
If an incident is determined to require additional resources, the fire department
should have as an objective the ability to respond with:
•
Additional units as needed (through its own resources or via automatic
and mutual aid).
Assignment of two (2) additional personnel to the rapid intervention team.
Assignment of one (1) as an incident safety officer.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 73
It is interesting to note that the four person companies discussed in some areas
of NFPA 1710 are not maintained in the description of primary tasks to be accomplished
on the fire ground – recognition that the requirements of the response in the field are
dynamic and do not fit neatly into size and shape of any particular response
configuration. These objectives apply to the initial and follow-up response for reported
structure fires. The document does not suggest that this response be mounted for all
incidents.
(2)
The City of Somerville Should Formally Adopt Locally Defined Service
Level Objectives.
The Somerville Fire Department includes a number of performance measures in
its annual budget, including average response times to emergency calls for service.
However, the City and the Fire Department have not identified or formally adopted
service level targets for initial response to emergency medical calls or fire incidents.
While the project team believes the standards utilized in the following sections are
appropriate for the City, service level targets should be adopted only after careful
consideration of local risks and the financial implications of maintaining those levels.
Recommendation: The City should formally adopt service level objectives. While
targets should be locally determined, the project team believes the City should
adopt a one-minute dispatch processing time and one-minute reflex time for 90%
of emergency calls.
(3)
The Current Fire Station Network Provides Excellent Coverage of the City
The next step for the project team was to assess the current fire station network
utilizing our GIS capabilities. The map showing station coverage is provided, below:
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 74
The project team assessed the capability of the Fire Department in terms of their
ability to cover the City. The map, and the statistics below, reflect only the ability of the
Somerville Fire Department. The other station locations are provided for reference only
The table, that follows, provides a summary of the coverage capabilities of the Fire
Department as measured by their ability to reach road miles within a period of time (four
minutes) with varying levels of personnel:
Number of Road Miles Within 4 Minutes of Emergency Response Personnel
Personnel
Street Miles
%
3 or more personnel
110
100%
9 or more personnel
94
85%
12 or more personnel
84
76%
18 or more personnel
26
24%
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 75
The map and table show that the Somerville Fire Department can cover a large
area of the City within the initial response time target of 4 minutes. Response
capabilities are greatest in the central areas of the City, with more limited response
coverage at the far east and north area. It also indicates that the Department can
provide an initial response of 3 personnel to multiple, simultaneous calls for service. In
conclusion, these data also indicate that the Department can assemble an initial
structure fire response rapidly – in fact, almost the entire City can be reached by a full
structure fire response within eight (8) minutes or less. Of course, this capability can
vary widely depending on the level of traffic volume in the City.
Recommendation: Maintain the current fire station network in the City. Consider
a new location, built with developer assistance, in the Assembly Square
development area. Move an existing company to that station.
3.
THE CITY’S FIRE STATIONS FACE MAJOR CHALLENGES IN TERMS OF
THEIR CONDITION. THE CITY SHOULD RETAIN AN ENGINEERING FIRM
TO CONDUCT A CONDITION ASSESSMENT.
The Matrix Consulting Group and SomerStat personnel toured the City’s fire
stations. Our tour of the facilities revealed the following examples:
•
Exterior walls with major visible cracks in brickwork and mortar, missing bricks,
etc.
•
Water penetration through roofs and walls.
•
Aging windows and doors which do little to prevent the penetration of water and
cold air.
•
Aging mechanical and electrical systems.
•
Personnel who are living in a “temporary” trailer that has been in place for a
decade. This was necessitated by air quality and other conditions in the station it
replaced.
•
Limited storage space.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 76
•
Limited office spaces, etc.
•
There is not an adequate facility for conducting fire training of any kind. The
single classroom that the Department has, at headquarters, is inadequate for
training. There is no facility in which the Department can provide for training with
hands-on skills without having to utilize space in a fire station or borrowed space.
•
The City should consider the adequacy of its emergency operations center
(EOC) as part of its overall facilities assessment.
Recommendation: The City should seek to have a professional condition
assessment performed by a competent engineering firm which can assess
structural, roofing, mechanical / electrical systems. The purpose of this
assessment should be to develop a formal plan for renovation or replacement of
fire facilities.
4.
OPPORTUNITIES SHOULD BE CONSIDERED FOR CONSOLIDATING FLEET
MAINTENANCE LOCATIONS AND / OR OPERATIONS.
The Fire Department provides for its own fleet maintenance within the
Headquarters station. The following paragraphs summarize the current situation:
•
The Department has a single mechanic who performs the full range of necessary
repairs and maintenance alone. This presents a major safety concern for the
Mechanic and a major risk management issue for the City and Fire Department.
•
The maintenance bay also doubles as storage area for large parts and tires,
presenting a major challenge for the Mechanic and necessitating the movement
of parts / tires to even extend the outriggers on the ladder trucks.
•
The pace of repairs can also be impacted by solo work – necessitating a number
of work arounds, movement of equipment, etc.
The City should consider the following solutions to these issues:
•
Move the mechanic from the headquarters facility to a joint facility with other
heavy equipment mechanics.
•
Maintain the current dedicated fire mechanic staffing of one position.
•
Support the work of the Fire Mechanic with other heavy equipment mechanics
from other departments. This will improve the safety of performing major repairs,
changing of tires, etc.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 77
•
The Department has had a second Fire Mechanic position that was eliminated in
2003. This position would improve the efficiency, effectiveness and safety of the
operation.
•
The second position would allow for the improvement of preventive maintenance
of Fire Department equipment and apparatus – this currently suffers due to the
demands on the sole Mechanic to address more urgent repairs.
Recommendation: The Fire Department should maintain its dedicated mechanic.
However, steps should be taken to shift the work location of the Mechanic to a
site shared with other heavy equipment repair mechanics. This will improve the
safety of the Fire Mechanic’s operations. In the interim, the Fire Department
could consider assigning a Firefighter to work as an assistant to the Mechanic.
Alternatively, a temporary mechanic could be hired to work with the Mechanic
part-time, allowing heavy repairs to be done when two personnel were available.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 78
5.
ASSESSMENT OF FIRE PREVENTION
AND PUBLIC EDUCATION
This chapter focuses on the fire prevention and public education efforts of the
Fire Department. The first section summarizes the findings of the project team as they
relate to these functions.
1.
ISSUES IDENTIFIED RELATING TO THE OPERATIONS OF THE FIRE
DEPARTMENT
The following exhibit summarizes the project team’s assessment of the
prevention and education functions in the Fire Department:
Performance Target
Strengths
Potential Improvements
FIRE PREVENTION
The Fire Marshal is a direct report
to the Fire Chief and holds
equivalent rank with other senior
command staff members.
!
The jurisdiction has adopted a
certified fire code.
!
The jurisdiction has ordinances
requiring built-in protection for
high-risk occupancies.
!
The Department routinely seeks
alarm and sprinkler upgrades
when developers request zoning
variances.
!
The Department has a dedicated
staff of plan reviewers and
inspectors.
!
Fire Prevention personnel plan
check site plans, fire protection
system plans and specifications,
and building permit plans for
compliance with the Uniform Fire
Code or NFPA Code.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 79
Plan checks in the Fire
Department are conducted
concurrently with those performed
by other participants in the plan
check process.
!
Jurisdiction-wide plan check
software (such as Permits Plus)
enables the Fire Department to
review and share comments with
other participants in the process,
and enables applicants to view in
process plan reviews.
!
Complicated plans including fire
suppression systems, fire pumps,
etc. are reviewed either by a
contract PE or are accepted with
an approved PE’s stamp on them.
!
The Department conducts
inspections in accord with state
and local ordinances.
!
The frequency of State mandated
fire prevention inspections by the
Division are in accordance with
the ordinances and codes
!
The Department has certified fire
investigators or works with
certified fire investigators from the
local law enforcement agency.
!
The Department has an
automated fire plan review,
inspection, permit and
investigation system.
!
Inspectors have laptops or other
field electronics devices that
enable them to directly input
inspection records, reducing
repetitious data entry.
!
The automated system is used to
produce an annual fire prevention
report.
!
The automated system supports
the creation and updating of pre-
fire plans by suppression
personnel.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 80
Fire prevention identifies high-risk
facilities and supports
suppression personnel in
conducting in-service inspections
and pre-fire plans.
!
The automated system supports
in-service inspections by
suppression personnel.
!
The Department has established
in-service inspection and pre-fire
plan goals each of its suppression
companies.
!
Fire Prevention staff work closely
with operations staff to identify
the cause of frequent calls for
service at specific addresses.
!
The Department has a public
education program to improve fire
safety knowledge and awareness.
!
The Department uses Fire
Prevention Week and the two
annual time changes as focal
points for public education.
!
The public education program
focuses on fire detector
installation, maintenance and
battery maintenance.
!
The public education program
also addresses other threats to
life and property including:
drowning prevention, stroke,
cardiac care.
!
The public education program
focuses on issues such as child
seat and bike safety.
!
Public education program works
in conjunction with law
enforcement to address gun
safety and other in-home issues.
!
A citizens fire academy is
available to the community.
!
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 81
CPR and other first aid programs
provided by the Fire Department
to the community at low or no
cost.
!
Engine companies, rescue crews,
etc. are directly involved in
prevention activities in their first
due area.
!
Prevention and public education
outreach is conducted with area
schools, assisted living facilities,
etc. to target at risk groups.
!
Specific programs are in place to
deal with juvenile fire setters
!
Company officers are trained to
handle basic cause and origin
determinations, including skills to
determine when an arson
investigator should be called on.
!
Arson investigators are State
certified and have also received
basic law enforcement training in
areas such as interrogation,
evidence collection, etc.
!
Fire and Police Departments
have specific individuals assigned
to serve as liaisons for handling
arson cases when there is a
criminal component.
!
Several of these major issues are addressed in the following sections.
2.
FIRE PREVENTION STAFF FACE MAJOR CHALLENGES IN THEIR
CURRENT WORK SPACE
The Fire Prevention and related staff are not currently housed in Fire
Headquarters (where there is not sufficient space) but rather share a trailer home with a
fire station crew. The following paragraphs document our key findings:
•
The space is very cramped – with desks, file cabinets, plan storage and other
assets all housed in one open space.
•
There is no space upon which plans can be fully laid out flat to be reviewed.
CITY OF SOMERVILLE, MASSACHUSETTS
Evaluation and Strategic Plan for the Fire Department
Matrix Consulting Group
Page 82
•
There is no meeting space that can be used by the Fire Department to meet with
other City Departments, contractors or others.
•
The storage spaces for plans, exacerbated by the lack of an electronic plans
system, is almost non-existent in the current office spaces. Plans are
permanently stored in tube racks, stacked on top of one another, etc.
•
Property files showing inspections, changes of use, permits, etc. are maintained
in file cabinets within the trailer – taking up the majority of the office space.
•
There is limited space for movement in the office, making it difficult for personnel
to interact, search for plans, etc.
Recommendation: The Fire Department, in conjunction with the City, should seek
to identify an alternative space for Fire Prevention more appropriate to their
needs. This would include, at minimum, space for individual work stations (large
enough to review plans), storage space separate from the office areas, and a
conference room space.
3.
THE CITY MUST EXAMINE THE INTERRELATIONSHIP BETWEEN THE FIRE
DEPARTMENT
AND
OTHER
CITY
DEPARTMENTS
INVOLVED
IN
DEVELOPMENT AND INSPECTIONAL SERVICES.
The City is currently seeking a consultant to evaluate the overall delivery of
inspections – including those performed by the Fire Department. A key focus for that
project will be to evaluate opportunities for enhancing the sharing of information and